STANDARD DATA DICTIONARY #120.57 -- GMRV VITALS PARAMETERS FILE 9/29/25 PAGE 1
STORED IN ^GMRD(120.57, (1 ENTRY) SITE: WWW.BMIRWIN.COM UCI: VISTA,VISTA (VERSION 5.0)
DATA NAME GLOBAL DATA
ELEMENT TITLE LOCATION TYPE
-----------------------------------------------------------------------------------------------------------------------------------
This file contains the various site configurable parameters for the Vitals/Measurements application.
DD ACCESS: @
RD ACCESS:
WR ACCESS: @
DEL ACCESS: @
LAYGO ACCESS: @
CROSS
REFERENCED BY: NAME(B)
120.57,.01 NAME 0;1 FREE TEXT (Required)
INPUT TRANSFORM: K:$L(X)>30!($L(X)<3)!'(X'?1P.E) X I $D(X) K:$D(^GMRD(120.57,1,0)) X S:'$D(^GMRD(120.57,1,0)) DINUM=
1
HELP-PROMPT: This field provides an arbitrary name for the single entry in this file.
DESCRIPTION:
This field provides an arbitrary name for the single entry in this file.
NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER
CROSS-REFERENCE: 120.57^B
1)= S ^GMRD(120.57,"B",$E(X,1,30),DA)=""
2)= K ^GMRD(120.57,"B",$E(X,1,30),DA)
This cross-reference is automatically created on .01 field.
120.57,1 QUICK ORDER PROTOCOL COUNTER Q0;1 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>9999)!(X<0)!(X?.E1"."1N.N) X
LAST EDITED: DEC 08, 1993
HELP-PROMPT: Type a Number between 0 and 9999, 0 Decimal Digits
DESCRIPTION:
This field contains a counter which is appended to the end of each quick order protocol.
DELETE AUTHORITY: ^
WRITE AUTHORITY: ^
READ AUTHORITY: ^
120.57,1.3 GMRV INITIALIZATION SWITCH INIT;1 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>100)!(X<0)!(X?.E1"."4N.N) X
LAST EDITED: DEC 08, 1993
HELP-PROMPT: Type a Number between 0 and 100, 3 Decimal Digits
DESCRIPTION:
This field contains a switch used by the GMRVINIT's ONLY. NO EDITING ALLOWED!!!
DELETE AUTHORITY: ^
WRITE AUTHORITY: ^
READ AUTHORITY: ^
120.57,2 STOP DATE DEFAULT 0;2 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>365)!(X<0)!(X?.E1"."1N.N) X
HELP-PROMPT: Type a Number between 0 and 365, 0 Decimal Digits
DESCRIPTION: This field stores the number of days allotted in between the start date of a vitals order and the
stop date.
120.57,3 CANCEL ON WARD TRANSFER 0;3 SET
'1' FOR YES;
'0' FOR NO;
HELP-PROMPT: Should these vitals orders be cancelled if a patient was transferred between wards? 1=Yes, and
0=No.
DESCRIPTION: This field indicates that a flag is present to cancel vital measurement orders when a patient
transfers between wards.
120.57,4 CANCEL ON SERVICE TRANSFER 0;4 SET
'1' FOR YES;
'0' FOR NO;
HELP-PROMPT: Should a patient's orders be cancelled if transferred between services? 1=Yes, and 0=No.
DESCRIPTION: This field indicates that a flag is present to cancel vital measurement orders when a patient
transfers between services.
120.57,5.1 ABNORMAL TEMPERATURE - HIGH 1;1 NUMBER (Required)
INPUT TRANSFORM: K:+X'=X!(X>120)!(X<45)!(X?.E1"."2N.N) X
HELP-PROMPT: Type a Number between 45 and 120, 1 Decimal Digit
DESCRIPTION: This field indicates the upper limit for an acceptable range of patient temperatures. The abnormal
high is equal to or greater than the value entered.
120.57,5.2 ABNORMAL TEMPERATURE - LOW 1;2 NUMBER (Required)
INPUT TRANSFORM: K:+X'=X!(X>120)!(X<45)!(X?.E1"."2N.N) X
HELP-PROMPT: Type a Number between 45 and 120, 1 Decimal Digit
DESCRIPTION: This field sets the lower limit for an acceptable range of patient temperatures. The abnormal low
is equal to or below that of the value entered.
120.57,5.3 ABNORMAL PULSE - HIGH 1;3 NUMBER (Required)
INPUT TRANSFORM: K:+X'=X!(X>300)!(X<0)!(X?.E1"."1N.N) X
HELP-PROMPT: Type a Number between 0 and 300, 0 Decimal Digits
DESCRIPTION: This field sets the upper limit of an acceptable pulse rate. The abnormal high is equal to or
greater than the value entered.
120.57,5.4 ABNORMAL PULSE - LOW 1;4 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>300)!(X<0)!(X?.E1"."1N.N) X
HELP-PROMPT: Type a Number between 0 and 300, 0 Decimal Digits
DESCRIPTION: This field sets the lower limit of an acceptable pulse rate. The abnormal low is equal to or lower
than the value entered.
120.57,5.5 ABNORMAL RESPIRATION - HIGH 1;5 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>100)!(X<0)!(X?.E1"."1N.N) X
HELP-PROMPT: Type a Number between 0 and 100, 0 Decimal Digits
DESCRIPTION: This field sets the upper limit of an acceptable respiration rate. The abnormal high is equal to or
greater than the value entered.
120.57,5.6 ABNORMAL RESPIRATION - LOW 1;6 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>100)!(X<0)!(X?.E1"."1N.N) X
HELP-PROMPT: Type a Number between 0 and 100, 0 Decimal Digits
DESCRIPTION: This field sets the lower limit of an acceptable respiration rate. The abnormal low is equal to or
lower than the value entered.
120.57,5.7 ABNORMAL SYSTOLIC - HIGH 1;7 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>300)!(X<0)!(X?.E1"."1N.N) X
HELP-PROMPT: Type a Number between 0 and 300, 0 Decimal Digits
DESCRIPTION: This field sets the upper limit for an acceptable systolic blood pressure. The abnormal high is
equal to or greater than the value entered.
120.57,5.71 ABNORMAL DIASTOLIC - HIGH 1;8 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>300)!(X<0)!(X?.E1"."1N.N) X
HELP-PROMPT: Type a Number between 0 and 300, 0 Decimal Digits
DESCRIPTION: This field sets the upper limit for an acceptable diastolic blood pressure. The abnormal high is
equal to or greater than the value entered.
120.57,5.8 ABNORMAL SYSTOLIC - LOW 1;9 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>300)!(X<0)!(X?.E1"."1N.N) X
HELP-PROMPT: Type a Number between 0 and 300, 0 Decimal Digits
DESCRIPTION: This field sets the lower limit for an acceptable systolic blood pressure. The abnormal low is
equal to or lower than the value entered.
120.57,5.81 ABNORMAL DIASTOLIC - LOW 1;10 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>300)!(X<0)!(X?.E1"."1N.N) X
HELP-PROMPT: Type a Number between 0 and 300, 0 Decimal Digits
DESCRIPTION: This field sets the lower limit for an acceptable diastolic blood pressure. The abnormal low is
equal to or lower than the value entered.
120.57,6.1 ABNORMAL CVP - HIGH 1;11 NUMBER (Required)
INPUT TRANSFORM: K:+X'=X!(X>100)!(X<-10)!(X?.E1"."2N.N) X
LAST EDITED: APR 16, 1997
HELP-PROMPT: Type a Number between -10 and 100, 1 Decimal Digit
DESCRIPTION: This field sets the upper limit of an acceptable central venous pressure rate. The abnormal high
is equal to or greater than the value entered.
120.57,6.2 ABNORMAL CVP - LOW 1;12 NUMBER (Required)
INPUT TRANSFORM: K:+X'=X!(X>100)!(X<-10)!(X?.E1"."2N.N) X
LAST EDITED: APR 16, 1997
HELP-PROMPT: Type a Number between -10 and 100, 1 Decimal Digit
DESCRIPTION: This field sets the lower limit of an acceptable central venous pressure. The abnormal low is
equal to or lower than the value entered.
120.57,6.3 ABNORMAL O2 SATURATION - LOW 1;13 NUMBER (Required)
INPUT TRANSFORM: K:+X'=X!(X>100)!(X<0)!(X?.E1"."1N.N) X
LAST EDITED: APR 16, 1997
HELP-PROMPT: Type a Number between 0 and 100, 0 Decimal Digits
DESCRIPTION: This field sets the lower limit of an acceptable oxygen saturation rate. The abnormal low is equal
to or lower than the value entered.
120.57,999 PHASE I COMPLETED PHASEI;1 SET
'1' FOR YES;
'0' FOR NO;
LAST EDITED: JUL 19, 1996
DESCRIPTION:
This field denotes whether the GMRV Site/Quality Conversion has completed.
DELETE AUTHORITY: @
WRITE AUTHORITY: @
120.57,999.1 PHASE II COMPLETED PHASEII;1 SET
'1' FOR YES;
'0' FOR NO;
LAST EDITED: JUL 19, 1996
DESCRIPTION:
This field denotes whether the GMRV Vitals Measurement Data Conversion has completed.
DELETE AUTHORITY: @
WRITE AUTHORITY: @
120.57,999.2 PHASE II LAST RECORD PHASEII;2 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>999999999)!(X<1)!(X?.E1"."1N.N) X
LAST EDITED: JUL 19, 1996
HELP-PROMPT: Type a Number between 1 and 999999999, 0 Decimal Digits
DESCRIPTION: This field will contain the number of the last record to be converted by the GMRV Vitals
Measurement Data Conversion, or it will be null if the conversion has completed or has not started.
DELETE AUTHORITY: @
WRITE AUTHORITY: @
INPUT TEMPLATE(S):
GMRV SITE FILE EDIT FEB 19, 1997@11:03 USER #0
PRINT TEMPLATE(S):
SORT TEMPLATE(S):
FORM(S)/BLOCK(S):