STANDARD DATA DICTIONARY #2005.71 -- IMAGING DICOM FIELDS FILE 3/24/25 PAGE 1 STORED IN ^MAG(2005.71, (1 ENTRY) SITE: WWW.BMIRWIN.COM UCI: VISTA,VISTA (VERSION 3.0) DATA NAME GLOBAL DATA ELEMENT TITLE LOCATION TYPE ----------------------------------------------------------------------------------------------------------------------------------- This file contains information for imaging DICOM fields that will be displayed when capture of an image is done within VI Capture Client. Added by Patch MAG*3.0*106 DD ACCESS: @ RD ACCESS: @ WR ACCESS: @ DEL ACCESS: @ LAYGO ACCESS: @ AUDIT ACCESS: @ CROSS REFERENCED BY: SOP(B) 2005.71,.01 SOP 0;1 FREE TEXT (Required) INPUT TRANSFORM: K:$L(X)>30!($L(X)<3)!'(X'?1P.E) X LAST EDITED: SEP 25, 2009 HELP-PROMPT: Enter SOP type (e.g. "TELEDERM"). It must be 3-30 characters in length. DESCRIPTION: SOP type for the image being converted to DICOM. CROSS-REFERENCE: 2005.71^B 1)= S ^MAG(2005.71,"B",$E(X,1,30),DA)="" 2)= K ^MAG(2005.71,"B",$E(X,1,30),DA) 2005.71,2 MODULE M;0 Multiple #2005.712 (Add New Entry without Asking) LAST EDITED: SEP 25, 2009 2005.712,.01 MODULE 0;1 FREE TEXT INPUT TRANSFORM: K:$L(X)>30!($L(X)<3) X LAST EDITED: SEP 25, 2009 HELP-PROMPT: Enter DICOM module name (e.g. "GENERAL STUDY"). It must be 3-30 characters in length. DESCRIPTION: DICOM module that contains multiple DICOM elements. CROSS-REFERENCE: 2005.712^B 1)= S ^MAG(2005.71,DA(1),"M","B",$E(X,1,30),DA)="" 2)= K ^MAG(2005.71,DA(1),"M","B",$E(X,1,30),DA) 2005.712,2 ELEMENT TAG E;0 Multiple #2005.713 (Add New Entry without Asking) LAST EDITED: JUN 14, 2010 2005.713,.01 ELEMENT TAG 0;1 FREE TEXT INPUT TRANSFORM: K:$L(X)>20!($L(X)<9) X LAST EDITED: JUN 14, 2010 HELP-PROMPT: Enter element tag (e.g. 0008,0021). It must be 9-20 characters in length. DESCRIPTION: The ELEMENT TAG is an ordered pair of numbers (a Group Number followed by an Element Number) that uniquely identifies each DICOM element. A comma is used as a separator between the Group Number and the Element Number. CROSS-REFERENCE: 2005.713^B 1)= S ^MAG(2005.71,DA(2),"M",DA(1),"E","B",$E(X,1,30),DA)="" 2)= K ^MAG(2005.71,DA(2),"M",DA(1),"E","B",$E(X,1,30),DA) 2005.713,2 ELEMENT NAME 0;2 FREE TEXT (Required) INPUT TRANSFORM: K:$L(X)>30!($L(X)<3) X LAST EDITED: SEP 25, 2009 HELP-PROMPT: Enter DICOM element name (e.g. "Series Date"). It must be 3-30 characters in length. DESCRIPTION: Descriptive name of the DICOM data element. 2005.713,3 VALUE MULTIPLICITY 0;3 FREE TEXT (Required) INPUT TRANSFORM: K:$L(X)>10!($L(X)<1) X LAST EDITED: JUN 10, 2010 HELP-PROMPT: Enter value multiplicity. It must be 1-10 characters in length. DESCRIPTION: Specifies the number of Values that can be encoded in the Value Field of a DICOM Data Element. If the number of Values that may be encoded in an element is variable, it shall be represented by two numbers separated by a dash; e.g., "1-10" means that there may be 1 to 10 Values in the element. 2005.713,4 VALUE REPRESENTATION 0;4 SET (Required) 'AE' FOR AE; 'AS' FOR AS; 'AT' FOR AT; 'CS' FOR CS; 'DA' FOR DA; 'DS' FOR DS; 'DT' FOR DT; 'FL' FOR FL; 'FD' FOR FD; 'IS' FOR IS; 'LO' FOR LO; 'LT' FOR LT; 'OB' FOR OB; 'OW' FOR OW; 'PN' FOR PN; 'SH' FOR SH; 'SL' FOR SL; 'SQ' FOR SQ; 'SS' FOR SS; 'ST' FOR ST; 'TM' FOR TM; 'UI' FOR UI; 'UL' FOR UL; 'US' FOR US; 'UT' FOR UT; LAST EDITED: JUN 10, 2010 HELP-PROMPT: Enter two characters value representation code. DESCRIPTION: The value of this field is a code for the "value representation" of the DICOM element. Possible values are taken from part 5, section 6 of the DICOM standard: AE: Application Entity AS: Age String AT: Attribute Tag CS: Code String DA: Date DS: Decimal String DT: Date Time FL: Floating Point FD: Floating Point Double IS: Integer String LO: Long String LT: Long Text OB: Other Byte String OW: Other Word String PN: Person Name SH: Short String SL: Signed Long SQ: Sequence of Items SS: Signed Short ST: Short Text TM: Time UI: Unique Identifier (UID) UL: Unsigned Long UN: Unknown US: Unsigned Short UT: Unlimited Text 2005.713,5 GUI CONTROL 0;5 SET (Required) 'E' FOR Edit Box; 'C' FOR Combo Box; 'M' FOR Memo; 'D' FOR Date; 'Z' FOR None; LAST EDITED: JUN 10, 2010 HELP-PROMPT: Enter the type of GUI control. DESCRIPTION: Delphi control type that will be used to present DICOM elements. INPUT TEMPLATE(S): PRINT TEMPLATE(S): SORT TEMPLATE(S): FORM(S)/BLOCK(S):