STANDARD DATA DICTIONARY #2005.71 -- IMAGING DICOM FIELDS FILE 9/29/25 PAGE 1
STORED IN ^MAG(2005.71, (1 ENTRY) SITE: WWW.BMIRWIN.COM UCI: VISTA,VISTA (VERSION 3.0)
DATA NAME GLOBAL DATA
ELEMENT TITLE LOCATION TYPE
-----------------------------------------------------------------------------------------------------------------------------------
This file contains information for imaging DICOM fields that will be displayed when capture of an image is done within VI Capture
Client.
Added by Patch MAG*3.0*106
DD ACCESS: @
RD ACCESS: @
WR ACCESS: @
DEL ACCESS: @
LAYGO ACCESS: @
AUDIT ACCESS: @
CROSS
REFERENCED BY: SOP(B)
2005.71,.01 SOP 0;1 FREE TEXT (Required)
INPUT TRANSFORM: K:$L(X)>30!($L(X)<3)!'(X'?1P.E) X
LAST EDITED: SEP 25, 2009
HELP-PROMPT: Enter SOP type (e.g. "TELEDERM"). It must be 3-30 characters in length.
DESCRIPTION:
SOP type for the image being converted to DICOM.
CROSS-REFERENCE: 2005.71^B
1)= S ^MAG(2005.71,"B",$E(X,1,30),DA)=""
2)= K ^MAG(2005.71,"B",$E(X,1,30),DA)
2005.71,2 MODULE M;0 Multiple #2005.712 (Add New Entry without Asking)
LAST EDITED: SEP 25, 2009
2005.712,.01 MODULE 0;1 FREE TEXT
INPUT TRANSFORM: K:$L(X)>30!($L(X)<3) X
LAST EDITED: SEP 25, 2009
HELP-PROMPT: Enter DICOM module name (e.g. "GENERAL STUDY"). It must be 3-30 characters in length.
DESCRIPTION:
DICOM module that contains multiple DICOM elements.
CROSS-REFERENCE: 2005.712^B
1)= S ^MAG(2005.71,DA(1),"M","B",$E(X,1,30),DA)=""
2)= K ^MAG(2005.71,DA(1),"M","B",$E(X,1,30),DA)
2005.712,2 ELEMENT TAG E;0 Multiple #2005.713 (Add New Entry without Asking)
LAST EDITED: JUN 14, 2010
2005.713,.01 ELEMENT TAG 0;1 FREE TEXT
INPUT TRANSFORM: K:$L(X)>20!($L(X)<9) X
LAST EDITED: JUN 14, 2010
HELP-PROMPT: Enter element tag (e.g. 0008,0021). It must be 9-20 characters in length.
DESCRIPTION: The ELEMENT TAG is an ordered pair of numbers (a Group Number followed by an Element Number)
that uniquely identifies each DICOM element. A comma is used as a separator between the Group
Number and the Element Number.
CROSS-REFERENCE: 2005.713^B
1)= S ^MAG(2005.71,DA(2),"M",DA(1),"E","B",$E(X,1,30),DA)=""
2)= K ^MAG(2005.71,DA(2),"M",DA(1),"E","B",$E(X,1,30),DA)
2005.713,2 ELEMENT NAME 0;2 FREE TEXT (Required)
INPUT TRANSFORM: K:$L(X)>30!($L(X)<3) X
LAST EDITED: SEP 25, 2009
HELP-PROMPT: Enter DICOM element name (e.g. "Series Date"). It must be 3-30 characters in length.
DESCRIPTION:
Descriptive name of the DICOM data element.
2005.713,3 VALUE MULTIPLICITY 0;3 FREE TEXT (Required)
INPUT TRANSFORM: K:$L(X)>10!($L(X)<1) X
LAST EDITED: JUN 10, 2010
HELP-PROMPT: Enter value multiplicity. It must be 1-10 characters in length.
DESCRIPTION: Specifies the number of Values that can be encoded in the Value Field of a DICOM Data Element.
If the number of Values that may be encoded in an element is variable, it shall be represented
by two numbers separated by a dash; e.g., "1-10" means that there may be 1 to 10 Values in the
element.
2005.713,4 VALUE REPRESENTATION 0;4 SET (Required)
'AE' FOR AE;
'AS' FOR AS;
'AT' FOR AT;
'CS' FOR CS;
'DA' FOR DA;
'DS' FOR DS;
'DT' FOR DT;
'FL' FOR FL;
'FD' FOR FD;
'IS' FOR IS;
'LO' FOR LO;
'LT' FOR LT;
'OB' FOR OB;
'OW' FOR OW;
'PN' FOR PN;
'SH' FOR SH;
'SL' FOR SL;
'SQ' FOR SQ;
'SS' FOR SS;
'ST' FOR ST;
'TM' FOR TM;
'UI' FOR UI;
'UL' FOR UL;
'US' FOR US;
'UT' FOR UT;
LAST EDITED: JUN 10, 2010
HELP-PROMPT: Enter two characters value representation code.
DESCRIPTION: The value of this field is a code for the "value representation" of the DICOM element.
Possible values are taken from part 5, section 6 of the DICOM standard:
AE: Application Entity
AS: Age String
AT: Attribute Tag
CS: Code String
DA: Date
DS: Decimal String
DT: Date Time
FL: Floating Point
FD: Floating Point Double
IS: Integer String
LO: Long String
LT: Long Text
OB: Other Byte String
OW: Other Word String
PN: Person Name
SH: Short String
SL: Signed Long
SQ: Sequence of Items
SS: Signed Short
ST: Short Text
TM: Time
UI: Unique Identifier (UID)
UL: Unsigned Long
UN: Unknown
US: Unsigned Short
UT: Unlimited Text
2005.713,5 GUI CONTROL 0;5 SET (Required)
'E' FOR Edit Box;
'C' FOR Combo Box;
'M' FOR Memo;
'D' FOR Date;
'Z' FOR None;
LAST EDITED: JUN 10, 2010
HELP-PROMPT: Enter the type of GUI control.
DESCRIPTION:
Delphi control type that will be used to present DICOM elements.
INPUT TEMPLATE(S):
PRINT TEMPLATE(S):
SORT TEMPLATE(S):
FORM(S)/BLOCK(S):