STANDARD DATA DICTIONARY #2006.04 -- ACQUISITION DEVICE FILE                                                      3/24/25    PAGE 1
STORED IN ^MAG(2006.04,  *** NO DATA STORED YET ***   SITE: WWW.BMIRWIN.COM   UCI: VISTA,VISTA                     (VERSION 3.0)   

DATA          NAME                  GLOBAL        DATA
ELEMENT       TITLE                 LOCATION      TYPE
-----------------------------------------------------------------------------------------------------------------------------------
 +---------------------------------------------------------------+ 
 |                                                               |
 | Property of the US Government.                                | 
 | No permission to copy or redistribute this software is given. | 
 | Use of unreleased versions of this software requires the user | 
 | to execute a written test agreement with the VistA Imaging    | 
 | Development Office of the Department of Veterans Affairs,     | 
 | telephone (301) 734-0100.                                     | 
 |                                                               |
 | The Food and Drug Administration classifies this software as  | 
 | a medical device.  As such, it may not be changed in any way. | 
 | Modifications to this software may result in an adulterated   | 
 | medical device under 21CFR820, the use of which is considered | 
 | to be a violation of US Federal Statutes.                     | 
 |                                                               |
 +---------------------------------------------------------------+
 
This file is used to manage and track the various devices used to "Import" images into the Vista Imaging network.  


              DD ACCESS: @
              RD ACCESS: @
              WR ACCESS: @
             DEL ACCESS: @
           LAYGO ACCESS: @
           AUDIT ACCESS: @

POINTED TO BY: ACQUISITION DEVICE field (#107) of the IMAGE File (#2005) 
               ACQUISITION DEVICE field (#107) of the IMAGE AUDIT File (#2005.1) 
               DEVICE field (#18) of the IMAGE SERIES File (#2005.63) 
               

CROSS
REFERENCED BY: NAME(B)



2006.04,.01   NAME                   0;1 FREE TEXT (Required)

              INPUT TRANSFORM:  K:$L(X)>30!(X?.N)!($L(X)<3)!'(X'?1P.E) X
              LAST EDITED:      APR 19, 2002 
              HELP-PROMPT:      NAME MUST BE 3-30 CHARACTERS, NOT NUMERIC OR STARTING WITH PUNCTUATION 
              DESCRIPTION:      This is the name of the IMPORT device that is used to interface newly captured diagnostic Images
                                and procedures to the clinical database.  

              CROSS-REFERENCE:  2006.04^B 
                                1)= S ^MAG(2006.04,"B",$E(X,1,30),DA)=""
                                2)= K ^MAG(2006.04,"B",$E(X,1,30),DA)


2006.04,1     SITE                   0;2 POINTER TO INSTITUTION FILE (#4)

              LAST EDITED:      APR 19, 2002 
              DESCRIPTION:      This field references Institution file to designate the facility that hosts this acquisition
                                device.  


2006.04,2     LOCATION               0;3 POINTER TO HOSPITAL LOCATION FILE (#44)

              LAST EDITED:      APR 19, 2002 
              DESCRIPTION:
                                This field references the physical hospital location of the device that captured the images.  



      FILES POINTED TO                      FIELDS

HOSPITAL LOCATION (#44)           LOCATION (#2)

INSTITUTION (#4)                  SITE (#1)



INPUT TEMPLATE(S):

PRINT TEMPLATE(S):

SORT TEMPLATE(S):

FORM(S)/BLOCK(S):