STANDARD DATA DICTIONARY #2006.5821 -- CT CONVERSION PARAMETERS FILE                                              3/24/25    PAGE 1
STORED IN ^MAGDICOM(2006.5821,  *** NO DATA STORED YET ***   SITE: WWW.BMIRWIN.COM   UCI: VISTA,VISTA                              

DATA          NAME                  GLOBAL        DATA
ELEMENT       TITLE                 LOCATION      TYPE
-----------------------------------------------------------------------------------------------------------------------------------
 +---------------------------------------------------------------+ 
 |                                                               |
 | Property of the US Government.                                | 
 | No permission to copy or redistribute this software is given. | 
 | Use of unreleased versions of this software requires the user | 
 | to execute a written test agreement with the VistA Imaging    | 
 | Development Office of the Department of Veterans Affairs,     | 
 | telephone (301) 734-0100.                                     | 
 |                                                               |
 | The Food and Drug Administration classifies this software as  | 
 | a medical device.  As such, it may not be changed in any way. | 
 | Modifications to this software may result in an adulterated   | 
 | medical device under 21CFR820, the use of which is considered | 
 | to be a violation of US Federal Statutes.                     | 
 |                                                               |
 +---------------------------------------------------------------+
 
The entries in this table document about the history of of the conversion parameters that were used to create Targa files from
DICOM streams.  The history in this table is used to reconstruct DICOM files when needed for export to external devices.  


              DD ACCESS: @
              RD ACCESS: @
              WR ACCESS: @
             DEL ACCESS: @
           LAYGO ACCESS: @
           AUDIT ACCESS: @

CROSS
REFERENCED BY: LOCATION(B)

INDEXED BY:    LOCATION & MANUFACTURER & MODEL & DATE (C)




2006.5821,.01 LOCATION               0;1 POINTER TO INSTITUTION FILE (#4) (Required)

              LAST EDITED:      OCT 03, 2007 
              HELP-PROMPT:      Identify the site for these CT conversion parameters. 
              DESCRIPTION:      The value of this field is a pointer to the Institution table (#4).  This pointer identifies the
                                site to which the current record applies.  

              CROSS-REFERENCE:  2006.5821^B 
                                1)= S ^MAGDICOM(2006.5821,"B",$E(X,1,30),DA)=""
                                2)= K ^MAGDICOM(2006.5821,"B",$E(X,1,30),DA)

              RECORD INDEXES:   C (#418)

2006.5821,2   MANUFACTURER           0;2 FREE TEXT

              INPUT TRANSFORM:  K:$L(X)>30!($L(X)<1) X
              LAST EDITED:      OCT 03, 2007 
              HELP-PROMPT:      Identify the manufacturer of this CT scanner. 
              DESCRIPTION:      The value of this field is a string. This string is the name of the manufacturer of the CT scanner
                                for which parameters are described in this record.  

              RECORD INDEXES:   C (#418)

2006.5821,3   MODEL                  0;3 FREE TEXT

              INPUT TRANSFORM:  K:$L(X)>30!($L(X)<1) X
              LAST EDITED:      OCT 03, 2007 
              HELP-PROMPT:      Identify the model name for this CT scanner. 
              DESCRIPTION:      The value of this field is a string.  This string identifies the model name of the CT scanner for
                                which the conversion parameters are described in this record.  

              RECORD INDEXES:   C (#418)

2006.5821,4   DATE                   0;4 DATE

              INPUT TRANSFORM:  S %DT="EX" D ^%DT S X=Y K:Y<1 X
              LAST EDITED:      OCT 03, 2007 
              HELP-PROMPT:      Specify the date on which these parameters were established. 
              DESCRIPTION:      The value of this field is a FileMan date (date only, no time).  This date identifies the day on
                                which the conversion parameters were established that are described in this record.  

              RECORD INDEXES:   C (#418)

2006.5821,5   CONVERSION PARAMETERS  0;5 FREE TEXT

              INPUT TRANSFORM:  K:$L(X)>100!($L(X)<1) X
              LAST EDITED:      OCT 03, 2007 
              HELP-PROMPT:      Enter the parameters that were applied for this CT scanner. 
              DESCRIPTION:      The value of this field is a string.  This string represents the conversion parameters (DICOM to
                                Targa conversion) that were applied for the CT scanner on the date specified elsewhere in this
                                record.  



      FILES POINTED TO                      FIELDS

INSTITUTION (#4)                  LOCATION (#.01)


File #2006.5821

  Record Indexes:

  C (#418)    RECORD    REGULAR    IR    LOOKUP & SORTING
      Short Descr:  Quick lookup by location, make, model and date
      Description:  This cross-reference keeps track of when parameters became active for a certain CT scanner.  
                     
                    The subscripts are: 
                       Location 
                       Manufacturer 
                       Model 
                       Date 
        Set Logic:  S ^MAGDICOM(2006.5821,"C",X(1),X(2),X(3),X(4),DA)=""
       Kill Logic:  K ^MAGDICOM(2006.5821,"C",X(1),X(2),X(3),X(4),DA)
       Whole Kill:  K ^MAGDICOM(2006.5821,"C")
             X(1):  LOCATION  (2006.5821,.01)  (Subscr 1)  (forwards)
             X(2):  MANUFACTURER  (2006.5821,2)  (Subscr 2)  (forwards)
             X(3):  MODEL  (2006.5821,3)  (Subscr 3)  (forwards)
             X(4):  DATE  (2006.5821,4)  (Subscr 4)  (forwards)


INPUT TEMPLATE(S):

PRINT TEMPLATE(S):

SORT TEMPLATE(S):

FORM(S)/BLOCK(S):