STANDARD DATA DICTIONARY #2006.623 -- MAG CR PARAMETER FILE                                                       3/24/25    PAGE 1
STORED IN ^MAG(2006.623,  *** NO DATA STORED YET ***   SITE: WWW.BMIRWIN.COM   UCI: VISTA,VISTA                    (VERSION 3.0)   

DATA          NAME                  GLOBAL        DATA
ELEMENT       TITLE                 LOCATION      TYPE
-----------------------------------------------------------------------------------------------------------------------------------
 +---------------------------------------------------------------+ 
 | Property of the US Government.                                | 
 | No permission to copy or redistribute this software is given. | 
 | Use of unreleased versions of this software requires the user | 
 | to execute a written test agreement with the VistA Imaging    | 
 | Development Office of the Department of Veterans Affairs,     | 
 | telephone (301) 734-0100.                                     | 
 |                                                               |
 | The Food and Drug Administration classifies this software as  | 
 | a medical device.  As such, it may not be changed in any way. | 
 | Modifications to this software may result in an adulterated   | 
 | medical device under 21CFR820, the use of which is considered | 
 | to be a violation of US Federal Statutes.                     | 
 +---------------------------------------------------------------+
 
This file is used to indicate that a correction for a historical problem with certain Fuji CR images should be applied when 
performing measurements on those images.  Entries should be added to this file to define precisely which CR Models/Software
versions need to have this correction applied.  The problem was that the Fuji CR image header stored incorrect values in the newer
Imager Pixel Spacing field (0018,1164), whereas the older field (Pixel Spacing--0028,0030) still carried the correct value.  Note
that the problem could appear in Fuji CR images, or images that may be identified as coming from DeJarnette ImageShare CR devices.  


              DD ACCESS: @
              RD ACCESS: @
              WR ACCESS: @
             DEL ACCESS: @
           LAYGO ACCESS: @
           AUDIT ACCESS: @

CROSS
REFERENCED BY: LOCATION(B)



2006.623,.01  LOCATION               0;1 FREE TEXT (Required)

              INPUT TRANSFORM:  K:$L(X)>6!($L(X)<3)!'(X'?1P.E) X
              LAST EDITED:      JUL 28, 2006 
              HELP-PROMPT:      Answer must be 3-6 characters in length. 
              DESCRIPTION:      Free-text version of the Location/Site code corresponding to the division where the images were
                                acquired.  

              CROSS-REFERENCE:  2006.623^B 
                                1)= S ^MAG(2006.623,"B",$E(X,1,30),DA)=""
                                2)= K ^MAG(2006.623,"B",$E(X,1,30),DA)


2006.623,1    MANUFACTURER           1;0 Multiple #2006.6231


2006.6231,.01   MANUFACTURER           0;1 FREE TEXT (Required) (Multiply asked)

                INPUT TRANSFORM:  K:$L(X)>33!($L(X)<3) X
                LAST EDITED:      JUL 28, 2006 
                HELP-PROMPT:      Enter Manufacturer Name exactly as it appears in the image header. 
                DESCRIPTION:
                                  Modality Manufacturer name.  

                CROSS-REFERENCE:  2006.6231^B 
                                  1)= S ^MAG(2006.623,DA(1),1,"B",$E(X,1,30),DA)=""
                                  2)= K ^MAG(2006.623,DA(1),1,"B",$E(X,1,30),DA)


2006.6231,1     MODEL                  1;0 Multiple #2006.62311

                DESCRIPTION:
                                  Model Name.  


2006.62311,.01    MODEL                  0;1 FREE TEXT (Required) (Multiply asked)

                  INPUT TRANSFORM:  K:$L(X)>40!($L(X)<3) X
                  LAST EDITED:      AUG 02, 2006 
                  HELP-PROMPT:      Enter Model Name exactly as it appears in the image header. 
                  DESCRIPTION:
                                    Model name.  

                  CROSS-REFERENCE:  2006.62311^B 
                                    1)= S ^MAG(2006.623,DA(2),1,DA(1),1,"B",$E(X,1,30),DA)=""
                                    2)= K ^MAG(2006.623,DA(2),1,DA(1),1,"B",$E(X,1,30),DA)


2006.62311,1      SOFTWARE VERSION       1;0 Multiple #2006.623111

                  DESCRIPTION:
                                    Software version as it appears in the Image header for this model 


2006.623111,.01     SOFTWARE VERSION       0;1 FREE TEXT (Required) (Multiply asked)

                    INPUT TRANSFORM:  K:$L(X)>15!($L(X)<1) X
                    LAST EDITED:      AUG 02, 2006 
                    HELP-PROMPT:      Enter Software Version exactly as it appears in the image header. 
                    DESCRIPTION:
                                      Software version as it appears in the Image header for this model 

                    CROSS-REFERENCE:  2006.623111^B 
                                      1)= S ^MAG(2006.623,DA(3),1,DA(2),1,DA(1),1,"B",$E(X,1,30),DA)=""
                                      2)= K ^MAG(2006.623,DA(3),1,DA(2),1,DA(1),1,"B",$E(X,1,30),DA)


2006.623111,1       USE OLD PIXEL SPACING VALUE 0;2 SET

                                      '1' FOR YES; 
                                      '0' FOR NO; 
                    LAST EDITED:      JUL 31, 2006 
                    HELP-PROMPT:      For this software version, enter YES to use the Old Pixel Spacing value (0028,0030) for 
                                      distance calculations. 
                    DESCRIPTION:      This is a flag to indicate that the older Pixel Spacing field's value should be used when
                                      calculating distance measurements for this model/software version.  This corrects for a bug
                                      in the Fuji CR image header in which the incorrect values were stored in the newer field
                                      (Imager Pixel Spacing--0018,1164), whereas the older field (Pixel Spacing--0028,0030) still
                                      carried the correct value; answering YES to this prompt enables the program to prefer the
                                      older field when calculating a measurement for images acquired with the Fuji bug.  









INPUT TEMPLATE(S):

PRINT TEMPLATE(S):
MAGD CR PARAM LIST            JUL 31, 2006@15:25  USER #0                                                     MAG CR PARAMETER LIST

SORT TEMPLATE(S):

FORM(S)/BLOCK(S):