STANDARD DATA DICTIONARY #395 -- DVB PARAMETERS FILE 3/24/25 PAGE 1 STORED IN ^DVB(395, *** NO DATA STORED YET *** SITE: WWW.BMIRWIN.COM UCI: VISTA,VISTA (VERSION 4) DATA NAME GLOBAL DATA ELEMENT TITLE LOCATION TYPE ----------------------------------------------------------------------------------------------------------------------------------- CROSS REFERENCED BY: ONE(B) 395,.01 ONE 0;1 NUMBER (Required) INPUT TRANSFORM: K:+X'=X!(X>1)!(X<0)!(X=0)!(X?.E1"."1N.N) X LAST EDITED: OCT 04, 1989 HELP-PROMPT: Type a Number between 0 and 1 NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER CROSS-REFERENCE: 395^B 1)= S ^DVB(395,"B",$E(X,1,30),DA)="" 2)= K ^DVB(395,"B",$E(X,1,30),DA) 395,.05 USE HINQ SCREENS? 0;5 SET 'y' FOR YES; 'n' FOR NO; LAST EDITED: JUL 12, 1993 DESCRIPTION: When this field is set to NO alert processing will not call HINQ screens 395,1 NETWORK DAY HQ;1 DATE DATE OF CURRENT NETWORK WORKDAY INPUT TRANSFORM: S %DT="ETX" D ^%DT S X=Y K:Y<1 X LAST EDITED: OCT 20, 1988 DESCRIPTION: This field contains the date of the current network workday. This will usually be the current day's date. On days that the network is unavailable (weekends and holidays) this field will contain the value of the previous network workday's date. For example, on a Sunday, this field will contain the date of the previous Friday. The value in this field is updated automatically by the system on workdays when a HINQ request is sent. It should not be necessary to edit this field. 395,2 LAST NET-WORKDAY HQ;2 DATE DATE OF LAST NETWORK WORKDAY INPUT TRANSFORM: S %DT="ETX" D ^%DT S X=Y K:Y<1 X LAST EDITED: NOV 01, 1988 DESCRIPTION: This field contains the date of the network workday that is previous to the current network workday. For example, on a Tuesday, it contains Monday's date. On a Sunday, the network workday is still Friday so Last Net-Workday will contain Thursday's date. When the parameter, NETWORK DAY, is updated on workdays, LAST NET-WORKDAY field is automatically updated to the value of the previous NETWORK DAY. Thus at times LAST NET-WORKDAY can be days apart from NETWORK DAY because a HINQ hasn't been requested to update the field. For example if NETWORK DAY is a Monday and LAST NET-WORKDAY is Friday and no HINQs are done until Thursday, on Thursday the NETWORK DAY will contain Thursday's date but LAST NET-WORKDAY will contain Monday's date. If a HINQ is done again on Friday then NETWORK DAY will be Friday's date and LAST NET-WORKDAY will be Thursday's. VIEW THE HINQ SUSPENSE FILE option displays entries beginning with the current day's date and going back to the LAST NET-WORKDAY'S date. It may be necessary to edit this field to contain an earlier date to extend the date range of this options. On the following workday, this field will get updated as usual to the previous NETWORK DAY'S date. SOURCE OF DATA: SYSTEM GENERATED 395,3 GMT OFFSET HQ;3 NUMBER Difference between time zone and GMT INPUT TRANSFORM: K:+X'=X!(X>10)!(X<0)!(X?.E1"."1N.N) X HELP-PROMPT: Type a Number between 0 and 10, 0 Decimal Digits DESCRIPTION: This entry is derived from the time zone field of the Kernel parameter file and the Mailman time zone file. If these files are not present it may be set to a positive number which is the difference between GMT and the sites current time zone, i.e. for Eastern daylight time it should be set to 4, Central daylight to 5, etc. This field is used to check the time of availability of the VBA computer and disable appropriate HINQ options if the VBA computer is not available. 395,4 NETWORK ENABLED HQ;4 SET NETWORK ENABLED PARAMETER '1' FOR YES; '0' FOR NO; DESCRIPTION: This parameter enables or disables the options which transmit requests to the VBA computer - GENERATE A HINQ REQUEST and PROCESS THE HINQ SUSPENSE FILE. Enter a yes to enable these options or a no to disable them. These options are automatically disabled during VBA computer non-workday hours. However, it may be necessary to disable these options temporarily if transmission problems are occurring. SOURCE OF DATA: ADT COORDINATOR OR SITE MANAGER 395,5 BATCH PROCESSING ENABLED HQ;5 SET BATCH PROCESSING PARAMETER '1' FOR YES; '0' FOR NO; DESCRIPTION: This parameter is set to a YES or NO by the system to enable or disable the option, PROCESS THE SUSPENSE FILE. The option is automatically disabled during VBA computer non-workday hours. When the option is selected during workday hours and this field contains a NO, a test of the network is automatically performed. This field will be set to a YES or NO value that indicates whether or not the HINQ Suspense file contains 'P'ending entries. The system sets this field. If this field is set to NO, queued jobs will quit before logging into the remote VBA. It may be manually reset to YES if there are pending entries in the suspense file. SOURCE OF DATA: SYSTEM GENERATED 395,6 USE HIGH INTENSITY? 0;3 SET '1' FOR YES; '0' FOR NO; LAST EDITED: FEB 02, 1990 HELP-PROMPT: YES will turn on the high intensity used in the HINQ screens, NO will turn it off 395,7 AUTO-REQUEUE OF IDCU ERRORS HQ;7 SET AUTO-REQUEUE OF IDCU ERRORS HINQ PARAMETER '1' FOR YES REQUEUE; '0' FOR NO REQUEUEING; DESCRIPTION: This parameter should be set to indicate to the system whether or not requests with communications errors should automatically be retransmitted to the VBA computer. Set this field to Y for YES REQUEUE or to N for NO REQUEUEING. If this parameter is set to REQUEUE requests will not be retransmitted if the Network is Disabled or the remote VBA computer is not available because of time, or Saturday, Sunday, Holidays. SOURCE OF DATA: ADT COORDINATOR OR SITE MANAGER 395,8 AUTO-REQUEUE LIMIT HQ;8 NUMBER AUTO-REQUEUE LIMIT PARAMETER INPUT TRANSFORM: K:+X'=X!(X>100)!(X<0)!(X?.E1"."1N.N) X LAST EDITED: JUN 09, 1993 HELP-PROMPT: Type a Number between 0 and 100, 0 Decimal Digits DESCRIPTION: This parameter should be set to a number between 0 and 100 to indicate to the system the total number of requeued jobs that can be Retransmitted to the VBA computer in a day. SOURCE OF DATA: ADT COORDINATOR OR SITE MANAGER NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER 395,9 REQUEUE COUNTER HQ;9 NUMBER COUNTER FOR AUTO-REQUEUE REQUESTS INPUT TRANSFORM: K:+X'=X!(X>999)!(X<0)!(X?.E1"."1N.N) X HELP-PROMPT: Type a Number between 0 and 999, 0 Decimal Digits DESCRIPTION: This field is a count of the number of batch processes that have been requeued by the system on a particular day. This field is incremented by the system each time a process is automatically requeued to the VBA computer. It is reset to zero by the system on workdays. To allow processes to be requeued, the number in this field must not be greater than the number in the AUTO-REQUEUE LIMIT field. If necessary, this field can be reset to zero by the user to allow additional processes to be requeued to the VBA computer. SOURCE OF DATA: SYSTEM GENERATED 395,10 HINQ MAIL MESSAGES 0;4 SET '1' FOR YES; '0' FOR NO; LAST EDITED: MAR 07, 1990 DESCRIPTION: This field will allow the site to turn on the mailing of HINQ mail messages when they process the suspense file. 395,11 NEW IDCU INTERFACE HQ;11 SET (Required) '1' FOR YES; '0' FOR NO; LAST EDITED: JUN 15, 1993 DESCRIPTION: When this field is set to YES, IDCU addressing is changed to access a new interface at the RDPCs. SOURCE OF DATA: SITE MANAGER 395,12 RDPC Time Difference HQ;12 NUMBER INPUT TRANSFORM: K:+X'=X!(X>10)!(X<-15)!(X?.E1"."1N.N) X LAST EDITED: SEP 12, 1989 HELP-PROMPT: Type a Number between -15 and 10, 0 Decimal Digits DESCRIPTION: This field should contain the time difference between the site and the RDPC where HINQ requests are sent. A site in the Eastern time zone sending to the Midwest RDPC should enter '-1' here. A site in the Pacific time zone sending to the Midwest RDPC should enter '2' here. If the RDPC is in the same time zone enter '0' here. Philadelphia is East, Hines, Midwest, and Austin are in Central time zones. SOURCE OF DATA: SITE MANAGER 395,13 ASK MEDICAL CENTER DIVISION HQ;13 SET '1' FOR YES; '0' FOR NO; DESCRIPTION: When a user enters a request in the HINQ suspense file 395.5, if the site is multi-divisional as defined in the ADT parameter file 43, field 11, the user will be prompted to enter a medical center division as defined in file 40.8. When the HINQ request is processed, the top line of the response will show the division name to aid in patient identification. SOURCE OF DATA: ADT COORDINATOR, SITE MANAGER 395,15 HINQ MAIL GROUP HQMG;0 POINTER Multiple #395.015 395.015,.01 HINQ MAIL GROUP 0;1 POINTER TO MAIL GROUP FILE (#3.8) LAST EDITED: FEB 01, 1989 NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER CROSS-REFERENCE: 395.015^B 1)= S ^DVB(395,DA(1),"HQMG","B",$E(X,1,30),DA)="" 2)= K ^DVB(395,DA(1),"HQMG","B",$E(X,1,30),DA) 395,16 IDCU ADDRESS HQVD;1 SET 'DMS.BDNE' FOR Philadelphia; 'DMS.BDNC' FOR Hines; 'DMS.BDNW' FOR Austin; 'DMS.BDNM' FOR Midwest; 'DMS.BONS' FOR Philadelphia; LAST EDITED: AUG 20, 1996 DESCRIPTION: This is the code for addressing the VBA computer through IDCU. SOURCE OF DATA: DISTRIBUTED 395,17 IDCU USERNAME-PASSWORD HQVD;2 FREE TEXT INPUT TRANSFORM: K:$L(X)>40!($L(X)<2) X LAST EDITED: JUL 05, 1990 HELP-PROMPT: Answer with IDCU USERNAME-PASSWORD DESCRIPTION: This field holds the IDCU USERNAME and PASSWORD Ex.(USERNAME-PASSWORD) 395,19 *HINQ device name HQVD;4 FREE TEXT INPUT TRANSFORM: K:$L(X)>30!($L(X)<1) X I $D(X) S %ZIS="NQ",IOP=X D ^%ZIS K:POP X S:$D(X) X=ION W:$D(X) " Stored int ernally as ",X S IOP="" D ^%ZIS K IOP,%ZIS LAST EDITED: AUG 29, 1999 HELP-PROMPT: ANSWER MUST BE 1-30 CHARACTERS IN LENGTH DESCRIPTION: This field should contain the name of the device which will be used to connect the DHCP computer to the IDCU for transmitting and receiving HINQ requests. This entry must be a name in the Device file. As of Patch DVB*4.0*34 this field is no longer used. NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER 395,20 *BATCH DEVICE NAME HQVD;5 FREE TEXT INPUT TRANSFORM: K:$L(X)>30!($L(X)<1) X I $D(X) S %ZIS="NQ",IOP=X D ^%ZIS K:POP X S:$D(X) X=ION W:$D(X) " Stored int ernally as ",X S IOP="" D ^%ZIS K IOP,%ZIS LAST EDITED: AUG 29, 1999 HELP-PROMPT: ANSWER MUST BE 1-30 CHARACTERS IN LENGTH DESCRIPTION: This field holds the device that is to be used when a batch process (process the HINQ Suspense file) is run. It should be different from HINQ device. As of Patch DVB*4.0*34 this field is no longer used. NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER 395,21 INSTITUTION/STATION NUMBER 0;2 FREE TEXT (Required) INPUT TRANSFORM: S DIC="^DIC(4,",DIC(0)="ENM" D ^DIC K:Y=-1 X I $D(X) S X=$P(^DIC(4,+Y,99),U,1) K:$L(X)>3!($L(X)<1) X LAST EDITED: FEB 15, 1989 HELP-PROMPT: ANSWER MUST BE 1-3 CHARACTERS IN LENGTH AND A CORRECT STATION NUMBER OR STATION NAME DESCRIPTION: This field holds the station number of the site. The HINQ program will get the station number it needs from this field. NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER 395,22 RDPC IP ADDRESS HQIP;1 FREE TEXT INPUT TRANSFORM: K:$L(X)>15!($L(X)<12)!'(X?1.3N1P1.3N1P1.3N1P1.3N) X LAST EDITED: SEP 16, 2005 HELP-PROMPT: Answer must be 14-15 characters in length. DESCRIPTION: This parameter contains the IP Address of the VBA Remote Data Processing Center. Users at a site will have HINQ passwords only valid at this RDPC. SOURCE OF DATA: ADT COORDINATOR OR SITE MANAGER NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER 395,23 AAC PORT DESIGNATOR HQIP;2 NUMBER INPUT TRANSFORM: K:+X'=X!(X>99999)!(X<0)!(X?.E1"."1N.N) X I X=99999 S X=1 LAST EDITED: SEP 16, 2005 HELP-PROMPT: Type a Number between 0 and 99999, 0 Decimal Digits DESCRIPTION: This field is a counter for the number of HINQ connections used at a site. The remainder of this number, divided by the number of available ports at the AAC, will determine which port to use for this HINQ session. The number will automatically reset after #99999. NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER FILES POINTED TO FIELDS MAIL GROUP (#3.8) HINQ MAIL GROUP:HINQ MAIL GROUP (#.01) INPUT TEMPLATE(S): PRINT TEMPLATE(S): SORT TEMPLATE(S): FORM(S)/BLOCK(S):