STANDARD DATA DICTIONARY #404.44 -- PCMM PARAMETER FILE 9/29/25 PAGE 1
STORED IN ^SCTM(404.44, (1 ENTRY) SITE: WWW.BMIRWIN.COM UCI: VISTA,VISTA (VERSION 5.3)
DATA NAME GLOBAL DATA
ELEMENT TITLE LOCATION TYPE
-----------------------------------------------------------------------------------------------------------------------------------
This is the parameter file for PCMM. There should be only one entry in this file. The IEN of this entry must be 1. If other
entries are added and the code not adjusted PCMM will not function properly. This file should only be updated or modified with the
help of NVS or a PCMM developer.
DD ACCESS: @
RD ACCESS: @
WR ACCESS: @
DEL ACCESS: @
LAYGO ACCESS: @
AUDIT ACCESS: @
CROSS
REFERENCED BY: PC STAFF AUTO INACTIVATE DATE(AC), NUMBER(B)
404.44,.01 NUMBER 0;1 NUMBER (Required)
INPUT TRANSFORM: K:+X'=X!(X>999)!(X<0)!(X?.E1"."1N.N) X
LAST EDITED: AUG 17, 1999
HELP-PROMPT: Type a Number between 0 and 999, 0 Decimal Digits
DESCRIPTION: This is a bogus field. There should only be one entry for this file. The IEN of this entry must
be 1 at this time. If other entries are added and the code not adjusted PCMM will not function
properly.
CROSS-REFERENCE: 404.44^B
1)= S ^SCTM(404.44,"B",$E(X,1,30),DA)=""
2)= K ^SCTM(404.44,"B",$E(X,1,30),DA)
404.44,12 DISABLE ALL CLIENTS 1;2 SET
'1' FOR YES;
'0' FOR NO;
LAST EDITED: AUG 17, 1999
DESCRIPTION: This field is set to yes if one wants to disable all PCMM GUI client workstations. A null value
will work the same as a zero.
404.44,13 DISABLE CLIENT AUTO-UPDATE 1;3 SET
'1' FOR YES;
'0' FOR NO;
LAST EDITED: AUG 23, 1999
DESCRIPTION: This field is used to indicate if client auto updating, registering the client in 404.46, can
happen.
404.44,14 RPC TIME LIMIT 1;4 NUMBER (Required)
INPUT TRANSFORM: K:+X'=X!(X>300)!(X<30)!(X?.E1"."1N.N) X
LAST EDITED: DEC 06, 1999
HELP-PROMPT: Type a Number between 30 and 300, 0 Decimal Digits
DESCRIPTION: This value represents the maximum number of seconds the client should wait for a response from the
server. This value should be set as low as possible consistent with allowing the client to avoid
timeout errors.
TECHNICAL DESCR: The value retrieved from this field is returned to the client by the SCMC VERIFY C/S SYNC remote
procedure. The client then uses this value to update the run time property RPCTimelimit in all
RPCBroker components.
404.44,15 HL7 TRANSMIT LIMIT 1;5 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>999999)!(X<1)!(X?.E1"."1N.N) X
LAST EDITED: DEC 06, 1999
HELP-PROMPT: Type a Number between 1 and 999999, 0 Decimal Digits
DESCRIPTION: This value represents the maximum number of records which will be transmitted during any given PCMM
HL7 transmission session. The default value is 999999. It is recommended this value be left AS
IS, unless the background HL7 messaging volume is adversely affecting system performance.
TECHNICAL DESCR: The value retrieved from this field is used by the SCMC PCMM HL7 TRANSMIT nightly background option
to regulate the maximum number of records to transmit.
404.44,16 HL7 AUTO RETRANSMIT PERIOD 1;6 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>999)!(X<1)!(X?.E1"."1N.N) X
LAST EDITED: FEB 03, 2000
HELP-PROMPT: Enter a number from 1 to 999.
DESCRIPTION: Enter the number of days that an auto retransmit of HL7 messages should occur if no ACK message is
received.
404.44,17 BASELINE RUN DATE 1;7 DATE
INPUT TRANSFORM: S %DT="EX" D ^%DT S X=Y K:Y<1 X
LAST EDITED: MAR 23, 2000
DESCRIPTION: This field contains the date the PCMM Baseline was run.
The Baseline can only run once at a site.
404.44,18 SHORT INTERVAL EXPIRATION DATE 1;8 DATE
INPUT TRANSFORM: S %DT="EX" D ^%DT S X=Y K:Y<1 X
LAST EDITED: JUL 12, 2006
HELP-PROMPT: Enter date short intervals expire (Debug ONLY)
DESCRIPTION: This field is used for debugging only. Normally it will hold no value. This field should not be
populated unless requested by EVS or Field Office personnel trouble shooting a PCMM issue.
When a date greater than the current date is entered in this field the PCMM automated inactivation
process will operate in short interval mode until the current date is greater than the date entered
in this field. The following PCMM processes are affected while a future date populates this field:
Inactivations occur every two days in lieu the standard mid-month and end of month.
PCMM auto inactivation notifications are generated nightly vs. monthly.
Inactivation grace window is reduced from thirty days to four.
404.44,19 PC STAFF AUTO INACTIVATE DATE 1;9 DATE
INPUT TRANSFORM: S %DT="EX" D ^%DT S X=Y K:Y<1 X
LAST EDITED: MAR 23, 2004
HELP-PROMPT: Cannot be edited
DESCRIPTION: Date Primary Care providers (PCPs and APs) and staff with inconsistent Person Class and Standard
Role
entries will be inactivated due to Primary Care business rules. Only physicians, NPs and PAs can
be Primary Care Providers (PCP.) Only Resident or Intern (Physicians,) NPs, and PAs can be
Associate Providers (AP.) This date is 6 Months after installation of patch SD*5.3*297.
TECHNICAL DESCR:
Cannot be edited. Is deleted after used to inactivate providers
UNEDITABLE
CROSS-REFERENCE: 404.44^AC
1)= S ^SCTM(404.44,"AC",$E(X,1,30),DA)=""
2)= K ^SCTM(404.44,"AC",$E(X,1,30),DA)
404.44,20 TEAM AUTO INACTIVATE 1;10 SET
'0' FOR NO;
'1' FOR YES;
LAST EDITED: FEB 15, 2006
DESCRIPTION: If this field is set to YES, then when a patient is inactivated from their primary care provider
assignment by the nightly job they will also be inactivated from the same TEAM and all other
positions on that TEAM.
If this field is set to NO, then when a patient is inactivated from their primary care panel by the
nightly job only thier primary care provider assignment will be inactivated.
The default value is YES.
404.44,21 PC STAFF INACTIVATION RUN DATE 1;11 DATE
INPUT TRANSFORM: S %DT="EX" D ^%DT S X=Y K:Y<1 X
LAST EDITED: JUL 24, 2006
HELP-PROMPT: DATE THAT PC STAFF WERE INACTIVATED BY THE NIGHTLY JOB
DESCRIPTION: This field records the date Primary Care providers are inactivated by the PCMM nightly job process.
Six months after the installation of patch SD*5.3*297 all primary care providers identified as
having an incorrect person class assignment will be inactivated. This is a one time, clean-up
event for PCMM Primary Care Providers.
This field is populated by a background process and should be manipulated through FileMan.
INPUT TEMPLATE(S):
PRINT TEMPLATE(S):
SORT TEMPLATE(S):
FORM(S)/BLOCK(S):