STANDARD DATA DICTIONARY #700.5 -- MEDICINE AUTO INSTRUMENT INTERFACE SUMMARY FILE 3/24/25 PAGE 1 STORED IN ^MCAR(700.5, *** NO DATA STORED YET *** SITE: WWW.BMIRWIN.COM UCI: VISTA,VISTA (VERSION 2.3) DATA NAME GLOBAL DATA ELEMENT TITLE LOCATION TYPE ----------------------------------------------------------------------------------------------------------------------------------- Contains one entry for each record transmitted from an auto instrument to DHCP. This file is used to print the Auto-Instrument Summary report. DD ACCESS: @ AUDIT ACCESS: @ CROSS REFERENCED BY: DATE/TIME OF TEST(B), DATE/TIME LATEST(C), NAME(PT) 700.5,.01 DATE/TIME OF TEST 0;1 DATE (Required) INPUT TRANSFORM: S %DT="T" D ^%DT S X=Y K:Y<1 X LAST EDITED: APR 27, 1989 HELP-PROMPT: Enter date/time of test. DESCRIPTION: Date/Time of Test NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER CROSS-REFERENCE: 700.5^B 1)= S ^MCAR(700.5,"B",$E(X,1,30),DA)="" 2)= K ^MCAR(700.5,"B",$E(X,1,30),DA) 700.5,.05 DATE/TIME INITIAL 0;6 DATE INPUT TRANSFORM: S %DT="T" D ^%DT S X=Y K:Y<1 X LAST EDITED: APR 27, 1989 HELP-PROMPT: Enter date/time of creation of entry in Bad Data File. DESCRIPTION: Date/Time of creation of entry in Bad Data File NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER 700.5,.06 DATE/TIME LATEST 0;9 DATE INPUT TRANSFORM: S %DT="T" D ^%DT S X=Y K:Y<1 X LAST EDITED: JUN 02, 1989 HELP-PROMPT: Enter date/time of latest transmission attempt. DESCRIPTION: This field identifies the Date/Time of latest transmission attempt. NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER CROSS-REFERENCE: 700.5^C 1)= S ^MCAR(700.5,"C",$E(X,1,30),DA)="" 2)= K ^MCAR(700.5,"C",$E(X,1,30),DA) This cross-reference allow sorting by the latest date of use. 700.5,1 INSTRUMENT NAME 0;2 FREE TEXT INPUT TRANSFORM: K:$L(X)>50!($L(X)<1) X HELP-PROMPT: Answer must be 1-50 characters in length. DESCRIPTION: Name of Auto instrument on-line when bad data transmission occurred 700.5,2 SSN 0;3 FREE TEXT INPUT TRANSFORM: K:$L(X)>10!($L(X)<9) X LAST EDITED: JUN 20, 1989 HELP-PROMPT: Answer must be 9-10 characters in length. DESCRIPTION: This field identifies SSN portion of data line as received for Auto Instrument 700.5,3 NAME 0;4 FREE TEXT INPUT TRANSFORM: K:X[""""!($A(X)=45) X I $D(X) K:$L(X)>50!($L(X)<1) X LAST EDITED: JUN 30, 1989 HELP-PROMPT: Answer must be 1-50 characters in length. DESCRIPTION: This field identifies Patient Name portion of data line received form Auto Instrument CROSS-REFERENCE: 700.5^PT 1)= S ^MCAR(700.5,"PT",$E(X,1,30),DA)="" 2)= K ^MCAR(700.5,"PT",$E(X,1,30),DA) This cross-reference allow the looks-up by name. 700.5,4 REASON FOR FAILURE 0;5 FREE TEXT INPUT TRANSFORM: K:$L(X)>1!($L(X)<1) X LAST EDITED: JUN 06, 1989 HELP-PROMPT: Answer must be 1 character in length. DESCRIPTION: Reason for initial failure to pass DHCP validity checks 700.5,5 ATTEMPTS 0;7 NUMBER INPUT TRANSFORM: K:+X'=X!(X>100000)!(X<1)!(X?.E1"."1N.N) X LAST EDITED: APR 17, 1989 HELP-PROMPT: Type a Number between 1 and 100000, 0 Decimal Digits DESCRIPTION: Number of attempts at transmission of same bad data record 700.5,6 ERR 0;8 FREE TEXT INPUT TRANSFORM: K:$L(X)>2!($L(X)<1) X LAST EDITED: JUN 07, 1989 HELP-PROMPT: Answer must be 1-2 characters in length. DESCRIPTION: This field contains the error code for the last transmission if the transmission is unsuccessful. 700.5,7 TYPE 0;10 FREE TEXT (Required) INPUT TRANSFORM: K:$L(X)>1!($L(X)<1)!'(X?1A.A) X LAST EDITED: MAY 11, 1990 HELP-PROMPT: Answer must be 1 character in length. DESCRIPTION: This field indicates the type of transmission: ie 'H' will be a Holter transmission, etc. INPUT TEMPLATE(S): PRINT TEMPLATE(S): SORT TEMPLATE(S): FORM(S)/BLOCK(S):