STANDARD DATA DICTIONARY #700.5 -- MEDICINE AUTO INSTRUMENT INTERFACE SUMMARY FILE                                3/24/25    PAGE 1
STORED IN ^MCAR(700.5,  *** NO DATA STORED YET ***   SITE: WWW.BMIRWIN.COM   UCI: VISTA,VISTA                      (VERSION 2.3)   

DATA          NAME                  GLOBAL        DATA
ELEMENT       TITLE                 LOCATION      TYPE
-----------------------------------------------------------------------------------------------------------------------------------
Contains one entry for each record transmitted from an auto instrument to DHCP.  This file is used to print the Auto-Instrument
Summary report.  


              DD ACCESS: @
           AUDIT ACCESS: @

CROSS
REFERENCED BY: DATE/TIME OF TEST(B), DATE/TIME LATEST(C), NAME(PT)



700.5,.01     DATE/TIME OF TEST      0;1 DATE (Required)

              INPUT TRANSFORM:  S %DT="T" D ^%DT S X=Y K:Y<1 X
              LAST EDITED:      APR 27, 1989 
              HELP-PROMPT:      Enter date/time of test. 
              DESCRIPTION:
                                Date/Time of Test 

              NOTES:            XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER

              CROSS-REFERENCE:  700.5^B 
                                1)= S ^MCAR(700.5,"B",$E(X,1,30),DA)=""
                                2)= K ^MCAR(700.5,"B",$E(X,1,30),DA)


700.5,.05     DATE/TIME INITIAL      0;6 DATE

              INPUT TRANSFORM:  S %DT="T" D ^%DT S X=Y K:Y<1 X
              LAST EDITED:      APR 27, 1989 
              HELP-PROMPT:      Enter date/time of creation of entry in Bad Data File. 
              DESCRIPTION:
                                Date/Time of creation of entry in Bad Data File 

              NOTES:            XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER


700.5,.06     DATE/TIME LATEST       0;9 DATE

              INPUT TRANSFORM:  S %DT="T" D ^%DT S X=Y K:Y<1 X
              LAST EDITED:      JUN 02, 1989 
              HELP-PROMPT:      Enter date/time of latest transmission attempt. 
              DESCRIPTION:
                                This field identifies the Date/Time of latest transmission attempt.  

              NOTES:            XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER

              CROSS-REFERENCE:  700.5^C 
                                1)= S ^MCAR(700.5,"C",$E(X,1,30),DA)=""
                                2)= K ^MCAR(700.5,"C",$E(X,1,30),DA)
                                This cross-reference allow sorting by the latest date of use.  



700.5,1       INSTRUMENT NAME        0;2 FREE TEXT

              INPUT TRANSFORM:  K:$L(X)>50!($L(X)<1) X
              HELP-PROMPT:      Answer must be 1-50 characters in length. 
              DESCRIPTION:
                                Name of Auto instrument on-line when bad data transmission occurred 


700.5,2       SSN                    0;3 FREE TEXT

              INPUT TRANSFORM:  K:$L(X)>10!($L(X)<9) X
              LAST EDITED:      JUN 20, 1989 
              HELP-PROMPT:      Answer must be 9-10 characters in length. 
              DESCRIPTION:
                                This field identifies SSN portion of data line as received for Auto Instrument 


700.5,3       NAME                   0;4 FREE TEXT

              INPUT TRANSFORM:  K:X[""""!($A(X)=45) X I $D(X) K:$L(X)>50!($L(X)<1) X
              LAST EDITED:      JUN 30, 1989 
              HELP-PROMPT:      Answer must be 1-50 characters in length. 
              DESCRIPTION:
                                This field identifies Patient Name portion of data line received form Auto Instrument 

              CROSS-REFERENCE:  700.5^PT 
                                1)= S ^MCAR(700.5,"PT",$E(X,1,30),DA)=""
                                2)= K ^MCAR(700.5,"PT",$E(X,1,30),DA)
                                This cross-reference allow the looks-up by name.  



700.5,4       REASON FOR FAILURE     0;5 FREE TEXT

              INPUT TRANSFORM:  K:$L(X)>1!($L(X)<1) X
              LAST EDITED:      JUN 06, 1989 
              HELP-PROMPT:      Answer must be 1 character in length. 
              DESCRIPTION:
                                Reason for initial failure to pass DHCP validity checks 


700.5,5       ATTEMPTS               0;7 NUMBER

              INPUT TRANSFORM:  K:+X'=X!(X>100000)!(X<1)!(X?.E1"."1N.N) X
              LAST EDITED:      APR 17, 1989 
              HELP-PROMPT:      Type a Number between 1 and 100000, 0 Decimal Digits 
              DESCRIPTION:
                                Number of attempts at transmission of same bad data record 


700.5,6       ERR                    0;8 FREE TEXT

              INPUT TRANSFORM:  K:$L(X)>2!($L(X)<1) X
              LAST EDITED:      JUN 07, 1989 
              HELP-PROMPT:      Answer must be 1-2 characters in length. 
              DESCRIPTION:
                                This field contains the error code for the last transmission if the transmission is unsuccessful.  


700.5,7       TYPE                   0;10 FREE TEXT (Required)

              INPUT TRANSFORM:  K:$L(X)>1!($L(X)<1)!'(X?1A.A) X
              LAST EDITED:      MAY 11, 1990 
              HELP-PROMPT:      Answer must be 1 character in length. 
              DESCRIPTION:
                                This field indicates the type of transmission: ie 'H' will be a Holter transmission, etc.  



INPUT TEMPLATE(S):

PRINT TEMPLATE(S):

SORT TEMPLATE(S):

FORM(S)/BLOCK(S):