STANDARD DATA DICTIONARY #700.5 -- MEDICINE AUTO INSTRUMENT INTERFACE SUMMARY FILE 9/29/25 PAGE 1
STORED IN ^MCAR(700.5, *** NO DATA STORED YET *** SITE: WWW.BMIRWIN.COM UCI: VISTA,VISTA (VERSION 2.3)
DATA NAME GLOBAL DATA
ELEMENT TITLE LOCATION TYPE
-----------------------------------------------------------------------------------------------------------------------------------
Contains one entry for each record transmitted from an auto instrument to DHCP. This file is used to print the Auto-Instrument
Summary report.
DD ACCESS: @
AUDIT ACCESS: @
CROSS
REFERENCED BY: DATE/TIME OF TEST(B), DATE/TIME LATEST(C), NAME(PT)
700.5,.01 DATE/TIME OF TEST 0;1 DATE (Required)
INPUT TRANSFORM: S %DT="T" D ^%DT S X=Y K:Y<1 X
LAST EDITED: APR 27, 1989
HELP-PROMPT: Enter date/time of test.
DESCRIPTION:
Date/Time of Test
NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER
CROSS-REFERENCE: 700.5^B
1)= S ^MCAR(700.5,"B",$E(X,1,30),DA)=""
2)= K ^MCAR(700.5,"B",$E(X,1,30),DA)
700.5,.05 DATE/TIME INITIAL 0;6 DATE
INPUT TRANSFORM: S %DT="T" D ^%DT S X=Y K:Y<1 X
LAST EDITED: APR 27, 1989
HELP-PROMPT: Enter date/time of creation of entry in Bad Data File.
DESCRIPTION:
Date/Time of creation of entry in Bad Data File
NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER
700.5,.06 DATE/TIME LATEST 0;9 DATE
INPUT TRANSFORM: S %DT="T" D ^%DT S X=Y K:Y<1 X
LAST EDITED: JUN 02, 1989
HELP-PROMPT: Enter date/time of latest transmission attempt.
DESCRIPTION:
This field identifies the Date/Time of latest transmission attempt.
NOTES: XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER
CROSS-REFERENCE: 700.5^C
1)= S ^MCAR(700.5,"C",$E(X,1,30),DA)=""
2)= K ^MCAR(700.5,"C",$E(X,1,30),DA)
This cross-reference allow sorting by the latest date of use.
700.5,1 INSTRUMENT NAME 0;2 FREE TEXT
INPUT TRANSFORM: K:$L(X)>50!($L(X)<1) X
HELP-PROMPT: Answer must be 1-50 characters in length.
DESCRIPTION:
Name of Auto instrument on-line when bad data transmission occurred
700.5,2 SSN 0;3 FREE TEXT
INPUT TRANSFORM: K:$L(X)>10!($L(X)<9) X
LAST EDITED: JUN 20, 1989
HELP-PROMPT: Answer must be 9-10 characters in length.
DESCRIPTION:
This field identifies SSN portion of data line as received for Auto Instrument
700.5,3 NAME 0;4 FREE TEXT
INPUT TRANSFORM: K:X[""""!($A(X)=45) X I $D(X) K:$L(X)>50!($L(X)<1) X
LAST EDITED: JUN 30, 1989
HELP-PROMPT: Answer must be 1-50 characters in length.
DESCRIPTION:
This field identifies Patient Name portion of data line received form Auto Instrument
CROSS-REFERENCE: 700.5^PT
1)= S ^MCAR(700.5,"PT",$E(X,1,30),DA)=""
2)= K ^MCAR(700.5,"PT",$E(X,1,30),DA)
This cross-reference allow the looks-up by name.
700.5,4 REASON FOR FAILURE 0;5 FREE TEXT
INPUT TRANSFORM: K:$L(X)>1!($L(X)<1) X
LAST EDITED: JUN 06, 1989
HELP-PROMPT: Answer must be 1 character in length.
DESCRIPTION:
Reason for initial failure to pass DHCP validity checks
700.5,5 ATTEMPTS 0;7 NUMBER
INPUT TRANSFORM: K:+X'=X!(X>100000)!(X<1)!(X?.E1"."1N.N) X
LAST EDITED: APR 17, 1989
HELP-PROMPT: Type a Number between 1 and 100000, 0 Decimal Digits
DESCRIPTION:
Number of attempts at transmission of same bad data record
700.5,6 ERR 0;8 FREE TEXT
INPUT TRANSFORM: K:$L(X)>2!($L(X)<1) X
LAST EDITED: JUN 07, 1989
HELP-PROMPT: Answer must be 1-2 characters in length.
DESCRIPTION:
This field contains the error code for the last transmission if the transmission is unsuccessful.
700.5,7 TYPE 0;10 FREE TEXT (Required)
INPUT TRANSFORM: K:$L(X)>1!($L(X)<1)!'(X?1A.A) X
LAST EDITED: MAY 11, 1990
HELP-PROMPT: Answer must be 1 character in length.
DESCRIPTION:
This field indicates the type of transmission: ie 'H' will be a Holter transmission, etc.
INPUT TEMPLATE(S):
PRINT TEMPLATE(S):
SORT TEMPLATE(S):
FORM(S)/BLOCK(S):