STANDARD DATA DICTIONARY #704.1111 -- OBS_VIEW_TERMINOLOGY FILE                                                   3/24/25    PAGE 1
STORED IN ^MDC(704.1111,  *** NO DATA STORED YET ***   SITE: WWW.BMIRWIN.COM   UCI: VISTA,VISTA                    (VERSION 1.0)   

DATA          NAME                  GLOBAL        DATA
ELEMENT       TITLE                 LOCATION      TYPE
-----------------------------------------------------------------------------------------------------------------------------------
This file maintains the relationships between views of OBS_VIEW File (#704.111) and terms of TERM File (#704.001).  
 
Note: Some field descriptions are directed to a programming and development audience.  


              DD ACCESS: @
              RD ACCESS: @
              WR ACCESS: @
             DEL ACCESS: @
           LAYGO ACCESS: @
           AUDIT ACCESS: @

PRIMARY KEY:        A (#99)
  Uniqueness Index: PK (#934)
       File, Field: 1) VIEW_ID (704.1111,.01)  2) TERM_ORDER (704.1111,.02)  3) TERM_ID (704.1111,.03)


INDEXED BY:    VIEW_ID & TERM_ORDER & TERM_ID (PK)




704.1111,.01  VIEW_ID                0;1 POINTER TO OBS_VIEW FILE (#704.111) (Required) (Key field)

              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Answer with a view identifier. 
              DESCRIPTION:      This field identifies an entry in the OBS VIEW File (#704.111); correlates this file entry with a
                                view.  

              RECORD INDEXES:   PK (#934)

704.1111,.02  TERM_ORDER             0;2 NUMBER (Required) (Key field)

              INPUT TRANSFORM:  K:+X'=X!(X>999)!(X<1)!(X?.E1"."1.N) X
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Type a number between 1 and 999, 0 Decimal Digits 
              DESCRIPTION:      This field indicates the order this term will display in that view identified by VIEW ID (field
                                #.01).  

              RECORD INDEXES:   PK (#934)

704.1111,.03  TERM_ID                0;3 POINTER TO TERM FILE (#704.101) (Key field)

              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Answer with a term identifier. 
              DESCRIPTION:
                                This field identifies an entry in the TERM File (#704.001); correlates this file entry with a term.  

              RECORD INDEXES:   PK (#934)

704.1111,.04  DISPLAY_NAME           0;4 FREE TEXT

              INPUT TRANSFORM:  K:$L(X)>50!($L(X)<1) X
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Answer must be 1-50 characters in length. 
              DESCRIPTION:      This is the name that will display to the user when the Clinical Flowsheets application shows this
                                term (TERM ID field #.03).  
                                 
                                A sample DISPLAY NAME could be "IV - Platelets".  


704.1111,.05  DISPLAY_WIDTH          0;5 NUMBER

              INPUT TRANSFORM:  K:+X'=X!(X>9999)!(X<80)!(X?.E1"."1.N) X
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Type a number between 80 and 9999, 0 Decimal Digits 
              DESCRIPTION:      This field is the number of pixels this term (TERM ID field #.03) will require to be displayed in
                                the Clinical Flowsheets application.  
                                 
                                A sample could be "120".  


704.1111,.06  DISPLAY_TOTAL          0;6 SET

                                '0' FOR NO; 
                                '1' FOR YES; 
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Answer whether a total should be displayed within the view. 
              DESCRIPTION:      This field indicates whether or not a summation of term (TERM ID field #.03) measurements will
                                display at the bottom of a grid shown via the Clinical Flowsheets application.  


704.1111,.07  DISPLAY_COUNT          0;7 SET

                                '0' FOR NO; 
                                '1' FOR YES; 
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Answer whether a "term count" should be displayed within the view. 
              DESCRIPTION:      This field indicates whether or not a count of terms (TERM ID field#.03) related to the view (VIEW
                                ID field #.01) will display at the bottom of the grid shown via the Clinical Flowsheets
                                application.  


704.1111,.08  DISPLAY_AVERAGE        0;8 SET

                                '0' FOR NO; 
                                '1' FOR YES; 
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Answer whether an average should be displayed within the view. 
              DESCRIPTION:      This field indicates whether or not an average of term (TERM ID field #.03) measurements will
                                display at the bottom of the grid shown via the Clinical Flowsheets application.  


704.1111,.09  DISPLAY_ONLY           0;9 SET

                                '0' FOR No; 
                                '1' FOR Yes; 
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Answer whether the term-value in this view is DISPLAY ONLY and cannot be edited. 
              DESCRIPTION:      This indicates whether or not this term (TERM ID field#.03) in this view (VIEW ID field#.01) is
                                only for display and reporting purposes and cannot be modified.  


704.1111,.1   DISPLAY_COLUMNS        0;10 NUMBER

              INPUT TRANSFORM:  K:+X'=X!(X>9)!(X<0)!(X?.E1"."1.N) X
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Type a number between 0 and 9, 0 Decimal Digits 
              DESCRIPTION:      When a "picklist" value is displayed for input in a radio group box this value is used to indicate
                                how many columns this term-value will be displayed in.  


704.1111,.11  DISPLAY_IN_CELL_TOTAL  0;11 SET

                                '0' FOR NO; 
                                '1' FOR YES; 
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Answer whether to display sub-totals within each time interval of the view. 
              DESCRIPTION:      This field indicates whether a sub-totals of indicated totals (e.g., total(#.06), count(#.07),
                                average(#.08) etc.) display within each TIME INTERVAL (file #704.111 field #.03) of this view (VIEW
                                ID #.01).  


704.1111,.12  DISPLAY_MINIMUM        0;12 SET

                                '0' FOR NO; 
                                '1' FOR YES; 
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Answer whether the least of the term-values should display within this view. 
              DESCRIPTION:      This field indicates whether or not the least of a list of term measurements will display at the
                                bottom of the grid shown via the Clinical Flowsheets application.  


704.1111,.13  DISPLAY_MAXIMUM        0;13 SET

                                '0' FOR NO; 
                                '1' FOR YES; 
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Answer whether the greatest of the term-values should display within this view. 
              DESCRIPTION:      This field indicates whether or not the greatest of a list of term measurements will display at the
                                bottom of the grid shown via the Clinical Flowsheets application.  


704.1111,.14  REQUIRED_TERM          0;14 SET

                                '0' FOR NO; 
                                '1' FOR YES; 
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Answer whether a term-value is required during view input. 
              DESCRIPTION:      This field indicates whether this term (TERM ID #.03) must be given a value when using this view
                                (VIEW ID #.01) for input.  


704.1111,.15  USE_DROPDOWN           0;15 SET

                                '0' FOR NO; 
                                '1' FOR YES; 
              LAST EDITED:      APR 21, 2009 
              HELP-PROMPT:      Answer whether this term's value will cause its display to be in a dropdown. 
              DESCRIPTION:      This field indicates whether or not a value for this term will necessitate the use of a "drop down"
                                instead of a "radio group".  
                                 
                                With long "picklists"  it is sometimes necessary to display items in a drop down instead of a radio
                                group.  



      FILES POINTED TO                      FIELDS

OBS_VIEW (#704.111)               VIEW_ID (#.01)

TERM (#704.101)                   TERM_ID (#.03)


File #704.1111

  Record Indexes:

  PK (#934)    RECORD    REGULAR    IR    LOOKUP & SORTING
       Unique for:  Key A (#99), File #704.1111
      Short Descr:  Uniqueness Index for Key 'A' of File #704.1111
      Description:  This will provide a quick reference to views and related terms.  
        Set Logic:  S ^MDC(704.1111,"PK",$E(X(1),1,38),$E(X(2),1,3),$E(X(3),1,38),DA)=""
       Kill Logic:  K ^MDC(704.1111,"PK",$E(X(1),1,38),$E(X(2),1,3),$E(X(3),1,38),DA)
       Whole Kill:  K ^MDC(704.1111,"PK")
             X(1):  VIEW_ID  (704.1111,.01)  (Subscr 1)  (Len 38)
             X(2):  TERM_ORDER  (704.1111,.02)  (Subscr 2)  (Len 3)
             X(3):  TERM_ID  (704.1111,.03)  (Subscr 3)  (Len 38)


INPUT TEMPLATE(S):

PRINT TEMPLATE(S):

SORT TEMPLATE(S):

FORM(S)/BLOCK(S):