STANDARD DATA DICTIONARY #776.999 -- HL7 MONITOR PARAMETERS FILE                                                  3/24/25    PAGE 1
STORED IN ^HLEV(776.999,  (1 ENTRY)   SITE: WWW.BMIRWIN.COM   UCI: VISTA,VISTA                                     (VERSION 1.6)   

DATA          NAME                  GLOBAL        DATA
ELEMENT       TITLE                 LOCATION      TYPE
-----------------------------------------------------------------------------------------------------------------------------------


              DD ACCESS: @
              RD ACCESS: @
              WR ACCESS: @
             DEL ACCESS: @
           LAYGO ACCESS: @
           AUDIT ACCESS: @

CROSS
REFERENCED BY: NAME(B)



776.999,.01   NAME                   0;1 FREE TEXT (Required)

              INPUT TRANSFORM:  K:$L(X)>30!(X?.N)!($L(X)<3)!'(X'?1P.E) X
              HELP-PROMPT:      NAME MUST BE 3-30 CHARACTERS, NOT NUMERIC OR STARTING WITH PUNCTUATION 
              DESCRIPTION:      This field holds the name of the parameter entry.  (Only one entry, internal entry number 1 should
                                exist.)  The value of this field has no affect on software execution.  

              CROSS-REFERENCE:  776.999^B 
                                1)= S ^HLEV(776.999,"B",$E(X,1,30),DA)=""
                                2)= K ^HLEV(776.999,"B",$E(X,1,30),DA)


776.999,2     STATUS-MASTER          0;2 SET

                                'A' FOR ACTIVE; 
                                'I' FOR INACTIVE; 
              LAST EDITED:      MAY 18, 2003 
              DESCRIPTION:      This field should be set to ACTIVE if the master job should run, and INACTIVE if the master job
                                should not run.  This field also controls individual monitor jobs.  (Note that setting this field
                                has no affect on queued future Taskman jobs - either the master job or the monitor jobst - until
                                these jobs start.  If this field is set to INACTIVE, when queued jobs start they check this field
                                and immediately stop.) 


776.999,3     REQUEUE MIN-MASTER JOB 0;3 NUMBER

              INPUT TRANSFORM:  K:+X'=X!(X>1440)!(X<5)!(X?.E1"."1N.N) X
              LAST EDITED:      AUG 08, 2003 
              HELP-PROMPT:      Type a Number between 5 and 1440, 0 Decimal Digits 
              DESCRIPTION:      When a master job runs, it's first action is to queue a new master job task in the future.  This
                                field is used to determine the number minutes in the future that the task is queued.  


776.999,4     PURGE HOURS            0;4 NUMBER

              INPUT TRANSFORM:  K:+X'=X!(X>12000)!(X<2)!(X?.E1"."1N.N) X
              LAST EDITED:      MAY 28, 2003 
              HELP-PROMPT:      Type a Number between 2 and 12000, 0 Decimal Digits 
              DESCRIPTION:      The Event Monitor system purges itself, retaining data in it's files for the number hours specified
                                by this field.  


776.999,6     STATUS-EVENT           0;6 SET

                                'A' FOR ACTIVE; 
                                'I' FOR INACTIVE; 
              LAST EDITED:      MAY 18, 2003 
              DESCRIPTION:      This field is similar to the STATUS-MASTER field, (and you should read the description of that
                                field), but only controls individual monitor jobs.  If this field is set to INACTIVE, no new
                                monitor jobs will be queued.  And, if any monitor jobs are already queued, they will stop
                                immediately when they start.  



INPUT TEMPLATE(S):
HLEV MASTER JOB ENTER/EDIT    JUN 03, 2003@05:16  USER #0    

PRINT TEMPLATE(S):

SORT TEMPLATE(S):

FORM(S)/BLOCK(S):