STANDARD DATA DICTIONARY #78.6 -- CAMERA/EQUIP/RM FILE                                                            3/24/25    PAGE 1
STORED IN ^RA(78.6,  *** NO DATA STORED YET ***   SITE: WWW.BMIRWIN.COM   UCI: VISTA,VISTA                         (VERSION 5.0)   

DATA          NAME                  GLOBAL        DATA
ELEMENT       TITLE                 LOCATION      TYPE
-----------------------------------------------------------------------------------------------------------------------------------
This file contains all the camera/equip/rm that may be used to perform imaging examinations.  The 'RADIOLOGY LOCATIONS' file uses
this file to indicate which camera/eqip/rm are allowable choices when the technologist attaches a camera/equip/rm to an exam s/he
has performed.  In other words, when the procedure is performed on a patient at a location, the only valid choices are those
cameras/equip/rms associated with that location.  
 
A camera/equip/rm can be associated with more than one location.  
 
Entries in this file should not be deleted. Adding new entries is always allowed.  
 
 Data Storage 
 ------------
The data for the 'CAMERA/EQUIP/RM' file is stored in the ^RA(78.6, global. At the present time this file is very static after
day-one initialization is complete.  However, it still should be journaled.  It should also be translated if the operating system
supports this function.  
 
 Input Templates 
 ---------------
The rad/nuc med package does not use any input templates associated with this file.  
 
 Print Templates 
 ---------------
The rad/nuc med package does not use any print templates associated with this file.  
 
 Sort Templates 
 --------------
The rad/nuc med package does not use any sort templates associated with this file.  



   APPLICATION GROUP(S): RA
IDENTIFIED BY: DESCRIPTION (#2)

POINTED TO BY: PRIMARY CAMERA/EQUIP/RM field (#18) of the EXAMINATIONS sub-field (#70.03) of the REGISTERED EXAMS sub-field 
                   (#70.02) of the RAD/NUC MED PATIENT File (#70) 
               DEFAULT CAMERA/EQUIP/RM field (#14) of the RAD/NUC MED PROCEDURES File (#71) 
               CAMERA/EQUIP/RM field (#.01) of the CAMERAS/EQUIP/RMS sub-field (#79.12) of the IMAGING LOCATIONS File (#79.1) 
               RAD PRIMARY CAMERA/EQUIP/RM field (#303) of the IMAGING SITE PARAMETERS File (#2006.1) 
               IMPORTER RAD CAMERA field (#122) of the DICOM GATEWAY PARAMETER File (#2006.563) 
               READY FOR INTERP TRIGGER VALUE field (#108) of the MAG VISTARAD SITE PARAMETERS File (#2006.69) 
               

CROSS
REFERENCED BY: CAMERA/EQUIP/RM(B), DESCRIPTION(C)



78.6,.01      CAMERA/EQUIP/RM        0;1 FREE TEXT (Required)

              CAMERA/EQUIPMENT/ROOM   
              INPUT TRANSFORM:  K:$L(X)>30!($L(X)<1)!'(X'?1P.E)!(X'?.ANP) X
              LAST EDITED:      JUN 03, 1994 
              HELP-PROMPT:      Enter a name for this camera/equip/rm, between 1 and 30 characters in length. 
              DESCRIPTION:      This field contains the name of this camera/equipment/room.  Names must be between 1 and 30
                                characters in length.  

              SOURCE OF DATA:   RAD/NUC MED COORDINATOR
              CROSS-REFERENCE:  78.6^B 
                                1)= S ^RA(78.6,"B",$E(X,1,30),DA)=""
                                2)= K ^RA(78.6,"B",$E(X,1,30),DA)
                                     Regular 'B' cross reference assigned by FileMan.  



78.6,2        DESCRIPTION            0;2 FREE TEXT

              DESCRIPTION OF THIS CAMERA/EQUIPMENT/ROOM   
              INPUT TRANSFORM:  K:X[""""!($A(X)=45) X I $D(X) K:$L(X)>40!($L(X)<3) X
              LAST EDITED:      JUN 03, 1994 
              HELP-PROMPT:      Enter a brief description, between 3 and 40 characters in length, to define the types of procedures 
                                performed. 
              DESCRIPTION:      This field is used to describe this camera/equipment/room and define what types of procedures may
                                be performed there.  'Triple Head Spec Scanner' is an example of a description.  Descriptions may
                                be between 3 and 40 characters in length.  

              SOURCE OF DATA:   COORDINATOR
              CROSS-REFERENCE:  78.6^C 
                                1)= S ^RA(78.6,"C",$E(X,1,30),DA)=""
                                2)= K ^RA(78.6,"C",$E(X,1,30),DA)
                                Allows look-up of camera/equip/rm by description.  




INPUT TEMPLATE(S):

PRINT TEMPLATE(S):

SORT TEMPLATE(S):

FORM(S)/BLOCK(S):