| TITLE | VALUE | |
|---|---|---|
| NAME | MAG DICOM PURGE HL7 | |
| DESCRIPTION | +---------------------------------------------------------------+ | Property of the US Government. | | No permission to copy or redistribute this software is given. | | Use of unreleased versions of this software requires the user | | to execute a written test agreement with the VistA Imaging | | Development Office of the Department of Veterans Affairs, | | telephone (301) 734-0100. | | | | The Food and Drug Administration classifies this software as | | a medical device. As such, it may not be changed in any way. | | Modifications to this software may result in an adulterated | | medical device under 21CFR820, the use of which is considered | | to be a violation of US Federal Statutes. | +---------------------------------------------------------------+ This RPC purges HL7 messages that were created before the date specified. | |
| TAG | HL7PURGE | |
| ROUTINE | MAGDRPC1 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 1 |
| INPUT PARAMETER | CUTOFF | |
| DESCRIPTION | The value of this parameter is a (FileMan) date. This date indicates the cut-off date before which all messages are to be purged. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | YES | |
| MAXIMUM DATA LENGTH | 20 | |
| RETURN VALUE TYPE | SINGLE VALUE | |
| RETURN PARAMETER DESCRIPTION | The value of this parameter is an integer number. This number is equal to the number of messages deleted. | |
| AVAILABILITY | RESTRICTED | |
| INACTIVE | ACTIVE | |
| CLIENT MANAGER | ||
| WORD WRAP ON | TRUE | |
| VERSION | 3.0 | |
| SUPPRESS RDV USER SETUP | No | |
| APP PROXY ALLOWED | ||