MAG DICOM CON UNREADLIST LOCK

TITLEVALUE
NAMEMAG DICOM CON UNREADLIST LOCK
DESCRIPTIONPer VHA Directive 2004-038, this RPC should not be modified.
+---------------------------------------------------------------+
| Property of the US Government. |
| No permission to copy or redistribute this software is given. |
| Use of unreleased versions of this software requires the user |
| to execute a written test agreement with the VistA Imaging |
| Development Office of the Department of Veterans Affairs, |
| telephone (301) 734-0100. |
| The Food and Drug Administration classifies this software as |
| a medical device. As such, it may not be changed in any way. |
| Modifications to this software may result in an adulterated |
| medical device under 21CFR820, the use of which is considered |
| to be a violation of US Federal Statutes. |
+---------------------------------------------------------------+

Lock or unlock an entry in TELEREADER READ/UNREAD LIST file (#2006.5849).
TAGLOCK
ROUTINEMAGDTR04
INPUT PARAMETERSSEQUENCE NUMBER1
INPUT PARAMETERUNREAD LIST POINTER
DESCRIPTIONA pointer to TELEREADER READ/UNREAD LIST file (#2006.5849)
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH

INPUT PARAMETERSSEQUENCE NUMBER2
INPUT PARAMETERLOCK FLAG
DESCRIPTIONLOCK FLAG = 1 TO CREATE THE LOCK
LOCK FLAG = 0 TO REMOVE THE LOCK
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH

INPUT PARAMETERSSEQUENCE NUMBER3
INPUT PARAMETERFULL NAME
DESCRIPTIONFULL NAME OF READER (LAST,FIRST FORMAT)
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH

INPUT PARAMETERSSEQUENCE NUMBER4
INPUT PARAMETERNAME ABBREVIATION
DESCRIPTIONINITIALS FOR THE READER
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH

INPUT PARAMETERSSEQUENCE NUMBER5
INPUT PARAMETERREMOTE DUZ
DESCRIPTIONDUZ of the Reader at acquisition site
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH

INPUT PARAMETERSSEQUENCE NUMBER6
INPUT PARAMETERLOCAL DUZ
DESCRIPTIONDUZ of the Reader at reading site
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH

INPUT PARAMETERSSEQUENCE NUMBER7
INPUT PARAMETERREADER SITE
DESCRIPTIONReading Site pointer to INSTITUTION file (#4)
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH

INPUT PARAMETERSSEQUENCE NUMBER8
INPUT PARAMETERREADER STATION
DESCRIPTIONReading Site's Station Number
PARAMETER TYPELITERAL
REQUIRED
MAXIMUM DATA LENGTH

RETURN VALUE TYPESINGLE VALUE
RETURN PARAMETER DESCRIPTION
AVAILABILITYRESTRICTED
INACTIVEACTIVE
CLIENT MANAGER
WORD WRAP ON
VERSION
SUPPRESS RDV USER SETUP
APP PROXY ALLOWED