TITLE | VALUE | |
---|---|---|
NAME | MAG DICOM CON UNREADLIST LOCK | |
DESCRIPTION | Per VHA Directive 2004-038, this RPC should not be modified. +---------------------------------------------------------------+ | Property of the US Government. | | No permission to copy or redistribute this software is given. | | Use of unreleased versions of this software requires the user | | to execute a written test agreement with the VistA Imaging | | Development Office of the Department of Veterans Affairs, | | telephone (301) 734-0100. | | The Food and Drug Administration classifies this software as | | a medical device. As such, it may not be changed in any way. | | Modifications to this software may result in an adulterated | | medical device under 21CFR820, the use of which is considered | | to be a violation of US Federal Statutes. | +---------------------------------------------------------------+ Lock or unlock an entry in TELEREADER READ/UNREAD LIST file (#2006.5849). | |
TAG | LOCK | |
ROUTINE | MAGDTR04 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 1 |
INPUT PARAMETER | UNREAD LIST POINTER | |
DESCRIPTION | A pointer to TELEREADER READ/UNREAD LIST file (#2006.5849) | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | ||
INPUT PARAMETERS | SEQUENCE NUMBER | 2 |
INPUT PARAMETER | LOCK FLAG | |
DESCRIPTION | LOCK FLAG = 1 TO CREATE THE LOCK LOCK FLAG = 0 TO REMOVE THE LOCK | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | ||
INPUT PARAMETERS | SEQUENCE NUMBER | 3 |
INPUT PARAMETER | FULL NAME | |
DESCRIPTION | FULL NAME OF READER (LAST,FIRST FORMAT) | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | ||
INPUT PARAMETERS | SEQUENCE NUMBER | 4 |
INPUT PARAMETER | NAME ABBREVIATION | |
DESCRIPTION | INITIALS FOR THE READER | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | ||
INPUT PARAMETERS | SEQUENCE NUMBER | 5 |
INPUT PARAMETER | REMOTE DUZ | |
DESCRIPTION | DUZ of the Reader at acquisition site | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | ||
INPUT PARAMETERS | SEQUENCE NUMBER | 6 |
INPUT PARAMETER | LOCAL DUZ | |
DESCRIPTION | DUZ of the Reader at reading site | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | ||
INPUT PARAMETERS | SEQUENCE NUMBER | 7 |
INPUT PARAMETER | READER SITE | |
DESCRIPTION | Reading Site pointer to INSTITUTION file (#4) | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | ||
INPUT PARAMETERS | SEQUENCE NUMBER | 8 |
INPUT PARAMETER | READER STATION | |
DESCRIPTION | Reading Site's Station Number | |
PARAMETER TYPE | LITERAL | |
REQUIRED | ||
MAXIMUM DATA LENGTH | ||
RETURN VALUE TYPE | SINGLE VALUE | |
RETURN PARAMETER DESCRIPTION | ||
AVAILABILITY | RESTRICTED | |
INACTIVE | ACTIVE | |
CLIENT MANAGER | ||
WORD WRAP ON | ||
VERSION | ||
SUPPRESS RDV USER SETUP | ||
APP PROXY ALLOWED |