MAG DICOM GET MACHINE ID

TITLEVALUE
NAMEMAG DICOM GET MACHINE ID
DESCRIPTION +---------------------------------------------------------------+
| Property of the US Government. |
| No permission to copy or redistribute this software is given. |
| Use of unreleased versions of this software requires the user |
| to execute a written test agreement with the VistA Imaging |
| Development Office of the Department of Veterans Affairs, |
| telephone (301) 734-0100. |
| |
| The Food and Drug Administration classifies this software as |
| a medical device. As such, it may not be changed in any way. |
| Modifications to this software may result in an adulterated |
| medical device under 21CFR820, the use of which is considered |
| to be a violation of US Federal Statutes. |
+---------------------------------------------------------------+

This Remote Procedure returns the internal entry number of
the entry for the specified computer in the table of registered
DICOM Gateways.
TAGGETID
ROUTINEMAGDRPC1
INPUT PARAMETERSSEQUENCE NUMBER1
INPUT PARAMETERHOSTNAME
DESCRIPTIONThe value of this parameter is a string. This string is the
"host name" of a computer. Many sites follow the standard
to use names like VHAxxxabcde, where xxx is a three-letter
abbreviation for the name of the site, and abcde is the
actual name of the computer.
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH30

RETURN VALUE TYPESINGLE VALUE
RETURN PARAMETER DESCRIPTIONThe value of the return parameter is a string.
When the numeric interpretation of this string is a negative
number, the value indicates an error condition, e.g.:
-1,No Hostname Specified

When the value of the return parameter is a positive number,
this number is the internal entry number for the entry
in the table of registered DICOM Gateways (#2006.5641).

When no entry exists for the specified computer, this RPC
will create a new entry.
AVAILABILITYRESTRICTED
INACTIVEACTIVE
CLIENT MANAGER
WORD WRAP ONFALSE
VERSION3
SUPPRESS RDV USER SETUP
APP PROXY ALLOWED