| TITLE | VALUE | |
|---|---|---|
| NAME | MAG STORE TEXT FILE DETAILS | |
| DESCRIPTION | +---------------------------------------------------------------+ | Property of the US Government. | | No permission to copy or redistribute this software is given. | | Use of unreleased versions of this software requires the user | | to execute a written test agreement with the VistA Imaging | | Development Office of the Department of Veterans Affairs, | | telephone (301) 734-0100. | | | | The Food and Drug Administration classifies this software as | | a medical device. As such, it may not be changed in any way. | | Modifications to this software may result in an adulterated | | medical device under 21CFR820, the use of which is considered | | to be a violation of US Federal Statutes. | +---------------------------------------------------------------+ This Remote Procedure updates the information about an image. Specifically, the fields for SERIES UID, SERIES NUMBER and IMAGE NUMBER (sequence within series) may be updated. | |
| TAG | STOREUID | |
| ROUTINE | MAGDOD01 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 1 |
| INPUT PARAMETER | IMAGE | |
| DESCRIPTION | The value of this parameter is a pointer to the IMAGE file (#2005). This pointer identifies the image for which information is to be updated. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | YES | |
| MAXIMUM DATA LENGTH | 20 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 2 |
| INPUT PARAMETER | SERIES | |
| DESCRIPTION | The value of this parameter is a string. This string, if non-empty, is the SERIES UID for the image specified. The format and meaning of a SERIES UID is specified in the DICOM standard. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | NO | |
| MAXIMUM DATA LENGTH | 64 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 3 |
| INPUT PARAMETER | SNUM | |
| DESCRIPTION | The value of this parameter is either 0 (zero) or a positive integer number. This number identifies the sequence of a series within a study. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | NO | |
| MAXIMUM DATA LENGTH | 10 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 4 |
| INPUT PARAMETER | INUM | |
| DESCRIPTION | The value of this parameter is either 0 (zero) or a positive integer number. This number identifies the sequence of the image within its series. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | NO | |
| MAXIMUM DATA LENGTH | 10 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 5 |
| INPUT PARAMETER | IMGUID | |
| DESCRIPTION | The value of this parameter is a string. This string meets the constraints of a DICOM Unique Identifier. This identifier uniquely identifies an image. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | NO | |
| MAXIMUM DATA LENGTH | 64 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 6 |
| INPUT PARAMETER | STUID | |
| DESCRIPTION | The value of this parameter is a string. This string meets the constraints of a DICOM Unique Identifier. This identifier uniquely identifies a study. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | NO | |
| MAXIMUM DATA LENGTH | 64 | |
| RETURN VALUE TYPE | SINGLE VALUE | |
| RETURN PARAMETER DESCRIPTION | The value of the return parameter is a string. When the specified values can be applied to the database, the value will be "0,OK". When the specified values cannot be applied to the database, the value will be a negative number, followed by a comma, followed by an error message. | |
| AVAILABILITY | RESTRICTED | |
| INACTIVE | ACTIVE | |
| CLIENT MANAGER | ||
| WORD WRAP ON | FALSE | |
| VERSION | 3 | |
| SUPPRESS RDV USER SETUP | ||
| APP PROXY ALLOWED | ||