TITLE | VALUE | |
---|---|---|
NAME | ORWGN MAXFRQ | |
DESCRIPTION | This RPC checks if the frequency of an ICD-10 search term is than the maximum allowed ICD-10 return values. | |
TAG | MAXFRQ | |
ROUTINE | ORWGN | |
INPUT PARAMETERS | SEQUENCE NUMBER | 1 |
INPUT PARAMETER | ORTRM | |
DESCRIPTION | This is the search term to be looked up. | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | 99 | |
RETURN VALUE TYPE | SINGLE VALUE | |
RETURN PARAMETER DESCRIPTION | Return Value: "1^22000" 2 pieces (first piece is 0 or 1, second piece is occurrence frequency of search term) First piece: 0 - Search term frequency is less than maximum allowed 1 - Search term frequency is greater than maximum allowed | |
AVAILABILITY | PUBLIC | |
INACTIVE | ACTIVE | |
CLIENT MANAGER | ||
WORD WRAP ON | FALSE | |
VERSION | ||
SUPPRESS RDV USER SETUP | ||
APP PROXY ALLOWED |