| TITLE | VALUE | |
|---|---|---|
| NAME | MAGV ATTACH IRRADIATION DOSE | |
| DESCRIPTION | +---------------------------------------------------------------+ | Property of the US Government. | | No permission to copy or redistribute this software is given. | | Use of unreleased versions of this software requires the user | | to execute a written test agreement with the VistA Imaging | | Development Office of the Department of Veterans Affairs, | | telephone (301) 734-0100. | | | | The Food and Drug Administration classifies this software as | | a medical device. As such, it may not be changed in any way. | | Modifications to this software may result in an adulterated | | medical device under 21CFR820, the use of which is considered | | to be a violation of US Federal Statutes. | +---------------------------------------------------------------+ This RPC allows irradiation dosage entries to be attached to a series. | |
| TAG | ATTACH | |
| ROUTINE | MAGVRD01 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 1 |
| INPUT PARAMETER | PATIENT | |
| DESCRIPTION | This is the patient identifier. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | ||
| MAXIMUM DATA LENGTH | ||
| INPUT PARAMETERS | SEQUENCE NUMBER | 2 |
| INPUT PARAMETER | PROCEDURE | |
| DESCRIPTION | This is the accession number of the procedure related to the irradiation dosage instance. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | ||
| MAXIMUM DATA LENGTH | ||
| INPUT PARAMETERS | SEQUENCE NUMBER | 3 |
| INPUT PARAMETER | TYPE | |
| DESCRIPTION | This is the type of irradiation instance - "CT" or "FLUORO". | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | ||
| MAXIMUM DATA LENGTH | ||
| INPUT PARAMETERS | SEQUENCE NUMBER | 4 |
| INPUT PARAMETER | STUDY UID | |
| DESCRIPTION | This is the study UID related to the irradiation dosage instance. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | ||
| MAXIMUM DATA LENGTH | ||
| INPUT PARAMETERS | SEQUENCE NUMBER | 5 |
| INPUT PARAMETER | SERUID | |
| DESCRIPTION | This is the series UID related to the irradiation dosage instance. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | ||
| MAXIMUM DATA LENGTH | ||
| INPUT PARAMETERS | SEQUENCE NUMBER | 6 |
| INPUT PARAMETER | IRRADIATION INSTANCE UID | |
| DESCRIPTION | This is the irradiation instance UID of a CT irradiation dosage instance. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | ||
| MAXIMUM DATA LENGTH | ||
| INPUT PARAMETERS | SEQUENCE NUMBER | 7 |
| INPUT PARAMETER | ATTRIBUTES | |
| DESCRIPTION | Input parameters are name-value pairs sent as successive integer subscripts in an array that should be passed in by reference. The values passed in should be in the format | |
| PARAMETER TYPE | LIST | |
| REQUIRED | ||
| MAXIMUM DATA LENGTH | ||
| RETURN VALUE TYPE | SINGLE VALUE | |
| RETURN PARAMETER DESCRIPTION | The first and only element of the return array will be formatted as [ERRORCODE]`[TEXT]`[ASSIGNED IEN]. An ERRORCODE value of 0 indicates success; all others indicate failure, as described in TEXT, and no IEN will be assigned. | |
| AVAILABILITY | RESTRICTED | |
| INACTIVE | ACTIVE | |
| CLIENT MANAGER | ||
| WORD WRAP ON | ||
| VERSION | ||
| SUPPRESS RDV USER SETUP | ||
| APP PROXY ALLOWED | ||