VPS STORE VITALS

TITLEVALUE
NAMEVPS STORE VITALS
DESCRIPTIONThis RPC is called by the Vetlink Kiosk (point of service) system.
This RPC stores the patient vitals sent from the Kiosk.
TAGWRITE
ROUTINEVPSVTL02
INPUT PARAMETERSSEQUENCE NUMBER1
INPUT PARAMETERVPSNUM
DESCRIPTIONPatient ID such as the patient SSN OR DFN OR ICN OR VIC/CAC.
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH25

INPUT PARAMETERSSEQUENCE NUMBER2
INPUT PARAMETERVPSTYP
DESCRIPTIONPatient ID TYPE such as SSN or DFN OR ICN OR VIC/CAC.
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH7

INPUT PARAMETERSSEQUENCE NUMBER3
INPUT PARAMETERVTYP
DESCRIPTIONVital type being stored. (i.e. BP for blood pressure)
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH10

INPUT PARAMETERSSEQUENCE NUMBER4
INPUT PARAMETERVVAL
DESCRIPTIONThe rate or value of the vital measurement.
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH20

INPUT PARAMETERSSEQUENCE NUMBER5
INPUT PARAMETERDTM
DESCRIPTIONDate / time vital measurement was taken.
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH14

INPUT PARAMETERSSEQUENCE NUMBER6
INPUT PARAMETERUSER
DESCRIPTIONUser that is entering the vitals
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH9

INPUT PARAMETERSSEQUENCE NUMBER7
INPUT PARAMETERLOC
DESCRIPTIONHospital location where the vitals where obtained.
PARAMETER TYPELITERAL
REQUIREDYES
MAXIMUM DATA LENGTH9

INPUT PARAMETERSSEQUENCE NUMBER8
INPUT PARAMETERQLFS
DESCRIPTIONAny qualifiers for this vital entry. Qualifiers are concatinated together
with colon seperator. (SITTING:R ARM)
PARAMETER TYPELITERAL
REQUIRED
MAXIMUM DATA LENGTH32

INPUT PARAMETERSSEQUENCE NUMBER9
INPUT PARAMETEROXY
DESCRIPTIONOxygen flow rate and percent value (2 l/min 95%)
PARAMETER TYPELITERAL
REQUIRED
MAXIMUM DATA LENGTH30

RETURN VALUE TYPESINGLE VALUE
RETURN PARAMETER DESCRIPTIONIf error returns 0^Error message, otherwise returns 1.
AVAILABILITY
INACTIVE
CLIENT MANAGER
WORD WRAP ONTRUE
VERSION
SUPPRESS RDV USER SETUP
APP PROXY ALLOWED