| TITLE | VALUE | |
|---|---|---|
| NAME | VPS STORE VITALS | |
| DESCRIPTION | This RPC is called by the Vetlink Kiosk (point of service) system. This RPC stores the patient vitals sent from the Kiosk. | |
| TAG | WRITE | |
| ROUTINE | VPSVTL02 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 1 |
| INPUT PARAMETER | VPSNUM | |
| DESCRIPTION | Patient ID such as the patient SSN OR DFN OR ICN OR VIC/CAC. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | YES | |
| MAXIMUM DATA LENGTH | 25 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 2 |
| INPUT PARAMETER | VPSTYP | |
| DESCRIPTION | Patient ID TYPE such as SSN or DFN OR ICN OR VIC/CAC. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | YES | |
| MAXIMUM DATA LENGTH | 7 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 3 |
| INPUT PARAMETER | VTYP | |
| DESCRIPTION | Vital type being stored. (i.e. BP for blood pressure) | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | YES | |
| MAXIMUM DATA LENGTH | 10 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 4 |
| INPUT PARAMETER | VVAL | |
| DESCRIPTION | The rate or value of the vital measurement. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | YES | |
| MAXIMUM DATA LENGTH | 20 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 5 |
| INPUT PARAMETER | DTM | |
| DESCRIPTION | Date / time vital measurement was taken. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | YES | |
| MAXIMUM DATA LENGTH | 14 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 6 |
| INPUT PARAMETER | USER | |
| DESCRIPTION | User that is entering the vitals | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | YES | |
| MAXIMUM DATA LENGTH | 9 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 7 |
| INPUT PARAMETER | LOC | |
| DESCRIPTION | Hospital location where the vitals where obtained. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | YES | |
| MAXIMUM DATA LENGTH | 9 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 8 |
| INPUT PARAMETER | QLFS | |
| DESCRIPTION | Any qualifiers for this vital entry. Qualifiers are concatinated together with colon seperator. (SITTING:R ARM) | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | ||
| MAXIMUM DATA LENGTH | 32 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 9 |
| INPUT PARAMETER | OXY | |
| DESCRIPTION | Oxygen flow rate and percent value (2 l/min 95%) | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | ||
| MAXIMUM DATA LENGTH | 30 | |
| RETURN VALUE TYPE | SINGLE VALUE | |
| RETURN PARAMETER DESCRIPTION | If error returns 0^Error message, otherwise returns 1. | |
| AVAILABILITY | ||
| INACTIVE | ||
| CLIENT MANAGER | ||
| WORD WRAP ON | TRUE | |
| VERSION | ||
| SUPPRESS RDV USER SETUP | ||
| APP PROXY ALLOWED | ||