TITLE | VALUE | |
---|---|---|
NAME | MBAA APPOINTMENT MAKE | |
DESCRIPTION | ||
TAG | MAKE | |
ROUTINE | MBAAMRP2 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 1 |
INPUT PARAMETER | DFN | |
DESCRIPTION | ||
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | 200 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 2 |
INPUT PARAMETER | CLINIC | |
DESCRIPTION | CLINIC IEN | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | 200 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 3 |
INPUT PARAMETER | APPDATE | |
DESCRIPTION | Appointment Date | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | 200 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 4 |
INPUT PARAMETER | TYPE | |
DESCRIPTION | PURPOSE OF VISIT | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | 200 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 5 |
INPUT PARAMETER | STYP | |
DESCRIPTION | This is the appointment type sub-category. It is a pointer to the Sharing Agreement Sub-Category file (#35.2). | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 999 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 7 |
INPUT PARAMETER | SRT | |
DESCRIPTION | This is the Scheduling Request Type. This is a set of codes: N = Next Available Appt C = Other than Next Available (Clinician Requested) P = Other than Next Available (Patient Requested) W = Walkin Appointment M = Multiple Appointment Booking A = Auto Rebook O = Other than Next Available Appointment | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 999 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 8 |
INPUT PARAMETER | OTHR | |
DESCRIPTION | This is a free text field with a maximum of 150 characters. This is also known as the Booking Notes on the expanded view of the appointment. | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 150 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 9 |
INPUT PARAMETER | CIO | |
DESCRIPTION | Code for Check In. Value can be null or CI. | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 200 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 10 |
INPUT PARAMETER | LAB | |
DESCRIPTION | If the patient needs to have labs before the appointment, this field is set to the labl appointment date/time. | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 200 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 11 |
INPUT PARAMETER | XRAY | |
DESCRIPTION | If the patient needs X-Rays before the appointment, this will be the date/time for the X-Ray appointment. | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 200 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 12 |
INPUT PARAMETER | EKG | |
DESCRIPTION | If the patient needs to have an EKG before the appointment, this will be the appointment date/time for the EKG. | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 200 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 13 |
INPUT PARAMETER | RQXRAY | |
DESCRIPTION | If the provider is requesting prior X-Rays be sent to the clinic prior to the appointment, this will be set to Y for Yes. Otherwise, it will be null. | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 200 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 14 |
INPUT PARAMETER | CON | |
DESCRIPTION | If the appointment is being made in response to a consult request, this parameter is set to the internal entry number for the consult request. | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 200 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 15 |
INPUT PARAMETER | LVL | |
DESCRIPTION | Flag that determines if an appointment can be made for a patient that already has an appointment scheduled for the same day as the current appointment request. Setting this parameter to 1 allows multiple appointments for the patient on the same day. | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 10 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 16 |
INPUT PARAMETER | DESDT | |
DESCRIPTION | This is the patient's desired date/time for an appointment. | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 200 | |
RETURN VALUE TYPE | ARRAY | |
RETURN PARAMETER DESCRIPTION | ||
AVAILABILITY | SUBSCRIPTION | |
INACTIVE | ||
CLIENT MANAGER | ||
WORD WRAP ON | ||
VERSION | 1 | |
SUPPRESS RDV USER SETUP | ||
APP PROXY ALLOWED | Yes |