TITLE | VALUE | |
---|---|---|
NAME | DSIYWO5 WOINIT INIT FIELDS | |
DESCRIPTION | WOINIT RPC to create a record for a new Work Order and set up fields depending on what kind of user is coming in. | |
TAG | WOINIT | |
ROUTINE | DSIYWO5 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 1 |
INPUT PARAMETER | TYPE | |
DESCRIPTION | TYPE Only used if coming from the Equipment screens - if so, TYPE="Q" "W" = Ward User (user entering data from a Ward - minimal entry) "Q" = Equipment Inventory (user coming from editing/adding a new piece of equipment in Equipment Inventory "E" = Engineering Entry - Engineer entering/maintaining WO's | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 1 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 2 |
INPUT PARAMETER | SHOPKEY | |
DESCRIPTION | SHOPKEY NO LONGER NEEDED The default shop key will be the receiving shop (default shop) for a VA. If TYPE="W" or "Q", the RPC will try to find a SHOPKEY, if not, one must be sent in | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 2 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 3 |
INPUT PARAMETER | EQIEN | |
DESCRIPTION | EQIEN If TYPE="Q" this value must be sent - Equipment IEN from ^ENG(6914) | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 11 | |
RETURN VALUE TYPE | ARRAY | |
RETURN PARAMETER DESCRIPTION | RETURN PARAMETER RET(1) = "-1^Error Message" If there are errors RET(1)="0^SHOPKEY NEEDED" - If this is returned, GUI MUST ask for a SHOPKEY or this RPC will not run - this means the default has not been set at this VA RET(FIELD) = FIELD# ^ TABLE NAME ^ INTERNAL ^ EXTERNAL | |
AVAILABILITY | PUBLIC | |
INACTIVE | ACTIVE | |
CLIENT MANAGER | ||
WORD WRAP ON | ||
VERSION | ||
SUPPRESS RDV USER SETUP | ||
APP PROXY ALLOWED |