| TITLE | VALUE | |
|---|---|---|
| NAME | DSIYWO5 WOINIT INIT FIELDS | |
| DESCRIPTION | WOINIT RPC to create a record for a new Work Order and set up fields depending on what kind of user is coming in. | |
| TAG | WOINIT | |
| ROUTINE | DSIYWO5 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 1 |
| INPUT PARAMETER | TYPE | |
| DESCRIPTION | TYPE Only used if coming from the Equipment screens - if so, TYPE="Q" "W" = Ward User (user entering data from a Ward - minimal entry) "Q" = Equipment Inventory (user coming from editing/adding a new piece of equipment in Equipment Inventory "E" = Engineering Entry - Engineer entering/maintaining WO's | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | NO | |
| MAXIMUM DATA LENGTH | 1 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 2 |
| INPUT PARAMETER | SHOPKEY | |
| DESCRIPTION | SHOPKEY NO LONGER NEEDED The default shop key will be the receiving shop (default shop) for a VA. If TYPE="W" or "Q", the RPC will try to find a SHOPKEY, if not, one must be sent in | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | NO | |
| MAXIMUM DATA LENGTH | 2 | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 3 |
| INPUT PARAMETER | EQIEN | |
| DESCRIPTION | EQIEN If TYPE="Q" this value must be sent - Equipment IEN from ^ENG(6914) | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | NO | |
| MAXIMUM DATA LENGTH | 11 | |
| RETURN VALUE TYPE | ARRAY | |
| RETURN PARAMETER DESCRIPTION | RETURN PARAMETER RET(1) = "-1^Error Message" If there are errors RET(1)="0^SHOPKEY NEEDED" - If this is returned, GUI MUST ask for a SHOPKEY or this RPC will not run - this means the default has not been set at this VA RET(FIELD) = FIELD# ^ TABLE NAME ^ INTERNAL ^ EXTERNAL | |
| AVAILABILITY | PUBLIC | |
| INACTIVE | ACTIVE | |
| CLIENT MANAGER | ||
| WORD WRAP ON | ||
| VERSION | ||
| SUPPRESS RDV USER SETUP | ||
| APP PROXY ALLOWED | ||