DSIYWO5 WOINIT INIT FIELDS

TITLEVALUE
NAMEDSIYWO5 WOINIT INIT FIELDS
DESCRIPTIONWOINIT

RPC to create a record for a new Work Order and set up fields depending
on what kind of user is coming in.
TAGWOINIT
ROUTINEDSIYWO5
INPUT PARAMETERSSEQUENCE NUMBER1
INPUT PARAMETERTYPE
DESCRIPTIONTYPE

Only used if coming from the Equipment screens - if so, TYPE="Q"
"W" = Ward User (user entering data from a Ward - minimal entry)
"Q" = Equipment Inventory (user coming from editing/adding a
new piece of equipment in Equipment Inventory
"E" = Engineering Entry - Engineer entering/maintaining WO's
PARAMETER TYPELITERAL
REQUIREDNO
MAXIMUM DATA LENGTH1

INPUT PARAMETERSSEQUENCE NUMBER2
INPUT PARAMETERSHOPKEY
DESCRIPTIONSHOPKEY

NO LONGER NEEDED
The default shop key will be the receiving shop (default shop) for a VA.
If TYPE="W" or "Q", the RPC will try to find a SHOPKEY, if not, one must
be sent in
PARAMETER TYPELITERAL
REQUIREDNO
MAXIMUM DATA LENGTH2

INPUT PARAMETERSSEQUENCE NUMBER3
INPUT PARAMETEREQIEN
DESCRIPTIONEQIEN

If TYPE="Q" this value must be sent - Equipment IEN from ^ENG(6914)
PARAMETER TYPELITERAL
REQUIREDNO
MAXIMUM DATA LENGTH11

RETURN VALUE TYPEARRAY
RETURN PARAMETER DESCRIPTIONRETURN PARAMETER

RET(1) = "-1^Error Message" If there are errors

RET(1)="0^SHOPKEY NEEDED" - If this is returned, GUI MUST ask for a
SHOPKEY or this RPC will not run - this means the default has not been
set at this VA

RET(FIELD) = FIELD# ^ TABLE NAME ^ INTERNAL ^ EXTERNAL
AVAILABILITYPUBLIC
INACTIVEACTIVE
CLIENT MANAGER
WORD WRAP ON
VERSION
SUPPRESS RDV USER SETUP
APP PROXY ALLOWED