TITLE | VALUE | |
---|---|---|
NAME | DSIYWO2 WOTCHED EDIT PRITECH | |
DESCRIPTION | WOTCHED RPC used to change the Technician Multi if the Primary Technician is changed | |
TAG | WOTCHED | |
ROUTINE | DSIYWO2 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 1 |
INPUT PARAMETER | PRITECH | |
DESCRIPTION | PRITECH Primary Technician's IEN to the ^ENG("EMP") file | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | 11 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 2 |
INPUT PARAMETER | PRISHOP | |
DESCRIPTION | PRISHOP This is the current IEN for the SHOP associated with the Primary Technician on the Work Order Screen. | |
PARAMETER TYPE | LITERAL | |
REQUIRED | YES | |
MAXIMUM DATA LENGTH | 10 | |
INPUT PARAMETERS | SEQUENCE NUMBER | 3 |
INPUT PARAMETER | DSIYTECH | |
DESCRIPTION | DSIYTECH Information from the Technician Multiple DSIYTECH = Tech IEN1 ^ Tech Hours 1 ^ Tech Shop 1^ ; Tech IEN2 ^ Tech Hours 2 ^ Tech Shop Internal 2 ; ...etc. | |
PARAMETER TYPE | LITERAL | |
REQUIRED | NO | |
MAXIMUM DATA LENGTH | 230 | |
RETURN VALUE TYPE | ARRAY | |
RETURN PARAMETER DESCRIPTION | RETURN PARAMETER DSIYRET(1) ="0 ^Warning message" if warnings DSIYRET(1)="-1^Error Message" if errors DSIYRET(#) = Date for new Technician Multiple p1: Assigned Tech Internal p2: Assigned Tech External p3: Hours Internal p4: Hours External p5: Shop Internal p6: Shop External | |
AVAILABILITY | ||
INACTIVE | ||
CLIENT MANAGER | ||
WORD WRAP ON | ||
VERSION | ||
SUPPRESS RDV USER SETUP | ||
APP PROXY ALLOWED |