| TITLE | VALUE | |
|---|---|---|
| NAME | ORWTIU VIEWCOPY | |
| DESCRIPTION | ||
| TAG | VIEWCOPY | |
| ROUTINE | ORWTIU | |
| INPUT PARAMETERS | SEQUENCE NUMBER | 1 |
| INPUT PARAMETER | DUZ | |
| DESCRIPTION | This is the user's DUZ. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | YES | |
| MAXIMUM DATA LENGTH | ||
| INPUT PARAMETERS | SEQUENCE NUMBER | 2 |
| INPUT PARAMETER | IEN | |
| DESCRIPTION | This is the TIU note IEN. It is used to determine if user is an author or cosigner of the note. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | NO | |
| MAXIMUM DATA LENGTH | ||
| INPUT PARAMETERS | SEQUENCE NUMBER | 3 |
| INPUT PARAMETER | INST | |
| DESCRIPTION | This is the Institution the user is logged into. | |
| PARAMETER TYPE | LITERAL | |
| REQUIRED | YES | |
| MAXIMUM DATA LENGTH | ||
| RETURN VALUE TYPE | SINGLE VALUE | |
| RETURN PARAMETER DESCRIPTION | RSLT= 0 - User is not allowed to view copy/paste information 1 - User is AUTHOR and note is UNSIGNED, or user is COSIGNER who has yet to SIGN the note and the AUTHOR has SIGNED the note. 2 - User has a user class of "CHIEF, HIMS", "CHIEF, MIS", "PRIVACY ACT OFFICER", or a special user class designated by the site. | |
| AVAILABILITY | ||
| INACTIVE | ||
| CLIENT MANAGER | ||
| WORD WRAP ON | ||
| VERSION | ||
| SUPPRESS RDV USER SETUP | ||
| APP PROXY ALLOWED | ||